Download Print this page
KitchenAid 53-3498 Installation Instructions Manual
KitchenAid 53-3498 Installation Instructions Manual

KitchenAid 53-3498 Installation Instructions Manual

Gas automatic dryer

Advertisement

Quick Links

INSTALLATIONINSTRUCTIONS
GAS
AUTOMATICDRYER
PLEASE READ ALL INSTALLATIONINSTRUCTIONS AND REQUIREMENTS BEFORE INSTALLING
WARNING : For your safety the information in this
_, ATTENTION : Pour votre securite, suivre les indica-
manual must be followed to minimize the risk of fire or
tions donnees dans ce manuel afin de reduire les risques
explosionor to preventproperty damage, personal injury or
d'incendie ou d'explosion et d'eviter dommages materiels,
loss of life.
blessures et deces.
• Do not store or use gasolineor other flammablevapors
Ne pas entreposer ni utiliser d'essence ou autres pro-
and liquids in the vicinity of this or any other appfiance,
duits et vapeurs inflammables A proximit6 de cette
secheuseou de tout autre appareil 61ectrom6nager.
WHATTO DO IFYOU SMELL GAS
QUE FAIRE S'ILY A UNE ODEUR DE GAZ
• Do not try to light any appliance.
• N'allumer aucun appareil.
• Do not touch any electrical switch;do not use any
• Ne toucher aucun commutateur6}etrique; ne pas utilis-
phone in your building,
er le tel6phone dans votre maison ou votre immeuble.
• Clear the room, building or area of all occupants.
• Fairesortir tousles occupants de la piece, du Iogement
ou immeuble,ou de la vicinit&
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• Appeler la compagnie de gas imm#diatement en util-
isant le telephone d'un voisin. Suivre Lesinstructions de
• If you cannot reach your gas supplier, call the fire
la compagnie de gaz.
department.
• En cas d'impossibilit6 de joindre la compagnie de gaz,
Installation and service must be performed by a qualified
appeler les pompiers.
installer,service agency or the gas supplier.
Le montage et les reparationsdoivent _tre faits par un
technicien qualifie, un prestatairede services ou la com-
pagnie de gaz.
FOR YOUR SAFETY AND THE PROPER OPERATION OF
YOUR NEW DRYER,THE DRYER MUST BE INSTALLED IN
ACCORDANCE WITH ALL THE INSTALLATIONREQUIRE-
MENTS.
- TOOLS REQUIRED -
SCREWDRIVER
All literature should be removed from inside dryer and saved for
W' DRIVER
PUTTY KNIFE
future reference.
PIPEWRENCH OR
PIPE SEAL COMPOUND
ADJUSTABLEWRENCH
DUCT TAPE
NOTE: DO NOT RAISE OR LOWER THE DRYER BY THE
BACKGUARD.
BACKGUARD
REMOVE
BRIPPING
MATERIALS
/
1, To remove the corrugated crate base, place your foot on the
base close to a leveling foot. Pushing down firmly with your
foot, tilt the dryer away from you.
2. Repeat process with all leveling feet (4). Remove excess
base by hand.
_i
_
3. Remove film covering backguard for shipping purposes.
Wipe clean of fingerprints.
I
GAS CONNECTIONS
II
The dryer must be installed in accordance with the Installation
_ _ ___
_
Requirements.EQUIPPEDFOR NATURALGAS. FOR LP GAS
INSTALLATION SEE PAGE2,
LEVELING
FOOT
CORRUGATED
CRATE
PLACE FOOT
P/N
53-3498
BASE
FOR LEVERAGE
1

Advertisement

loading

Summary of Contents for KitchenAid 53-3498

  • Page 1 Wipe clean of fingerprints. base by hand. GAS CONNECTIONS Requirements.EQUIPPEDFOR NATURALGAS. FOR LP GAS INSTALLATION SEE PAGE2, LEVELING FOOT The dryer must be installed in accordance with the Installation _ _ ___ CORRUGATED CRATE PLACE FOOT 53-3498 BASE FOR LEVERAGE...
  • Page 2: General Information

    PLEASE READ All Installation Instructions and Requirements Before Installing. GENERAL INFORMATION INSTALLATION IN RESIDENTIAL GARAGE It is recommended that a qualified service technician install Flammable Vapors - Vapors from spilled gasoline can be your dryer, ignited by a clothes dryer, a water heater, or other non- sealed gas heating appliance.
  • Page 3: Shutdown Instructions

    CONNECTIONS SUPPLY PRESSURE TESTING Pressure testing of the Gas Supply Piping System: INSTALLATION MUST CONFORM WITH LOCAL t. Test pressure in excess of _ psig (3.45 KPA).The dryer must be CODES or in the absence of local codes, with the latest disconnected from the gas supply piping system at the inlet gas revision of the National Fuel Gas Code, ANSI Z223.1 or...
  • Page 4 1. LEVELING 2. STABILITY 3. SERVICE CONNECTION COVER P LATE-- WITH HANDS TO CHECKIF FOOT LEVEL AND STABLE ROCK DRYER >_ DRYER VENTPIPE Set all leveling feet at same height. A Place dryer in the location where it will GASINLET _ minimum of '/_"clearance between the be used.
  • Page 5 EXHAUST VENTING RECUIREVENTS ALL GAS DRYERS MUST BE VENTED OUTDOORS VENTHOOD TYPE FIRE HAZARD Number of NEVER CONNECT EXHAUST INTO ANY GAS VENT, 90°Turns Separated b y DUCT, CHIMNEY, WALL, CEILING, A'R'IC, CON- at least4ff. FINED OR CONCEALED SPACE, BEDROOM, BATH- of Straight R un -.-P[ 4"...
  • Page 6: Final Check Out

    Saw a 4_A " hole in floor and position dryer. A 4" 90 degree elbow and length of 4" metal exhaust pipe must be purchased. Shorten the rear exhaust pipe inside the 10. Secure the shortened pipe to the blower housing with a dryer as required.