Preparation Of The Dryer; Confirming Heat Source Operation; Dryer Airflow - LG DLE0442W Owner's Manual

Electric and gas dryer
Hide thumbs Also See for DLE0442W:
Table of Contents

Advertisement

Prior to the first use of this appliance,
use all-
purpose
cleaning products
or a solution of detergent
and water, with damp clothes to remove from the
inside of the dryer drum/drying
compartment
any
dust or dirt that may have accumulated
the inside of
the dryer.
Plug-in your dryer after reviewing
the
following
parts on your dryer's
Electrical
Requirements.
Effective dryer operation
requires appropriate
dryer
airflow. The adequacy
of the airflow can be
measured
by evaluating
the static pressure.
Static
pressure in the exhaust
duct can be measured
with a
manometer,
placed on the exhaust
duct
approximately
2 ft. (60.9 cm) from the dryer.
Static
pressure in the exhaust
duct should not exceed 0.6
inches (1.5 cm). The dryer should be checked
with
the dryer running with no load.
Measuring Static pressure
Confirming
Heat Source
in Gas Dryers
Close the door to the dryer drum/drying
compartment
and, alter completing
all steps in this
manual for proper installation
of this dryer, start the
dryer on a heat setting, as described
more tully in
the operating
instructions
that accompany
the dryer.
Alter the dryer starts, the igniter will glow red and
the main burner will ignite.
Warning:
If all air is not purged from the gas line,
the gas igniter may go off before the gas and the
main burner have ignited.
If this happens,
the
igniter will re-attempt
gas ignition after
approximately
two minutes.
Confirming
Heat Source
in Electric
Dryers
Close the door to the dryer drum/drying
compartment
and, alter completing
all steps in this
manual for proper installation
of this dryer, start the
dryer on a heat setting, as described
more tully in
the operating
instructions
that accompany
the dryer.
The exhaust
air or the exhaust pipe should be warm
alter the dryer has been operating
for three minutes.
Manometer
Exhaust Duct
MAXIMUM STATIC
PRESSURE IN
WATER COLUMN
0.6 inche (1.5 cm)
22