Before you call for service...
GEAppliances.com
Troubleshooting tips. Save time and money! Review the chart below
first and you may not need to call for service.
Possible Causes
What To Do
The air conditioner
• Make sure the air conditioner
plug is pushed
completely
is unplugged,
into the outlet.
The fuse is blown/circult
• Check
the house fltse/circuit
breaker
box and replace
breaker
is tripped,
the fi]se or reset tim breaker.
Power
failure.
• If power
failure
occurs,
turn
the air conditoner
OFF.
When
power
is restored,
wait 3 minutes
to restart
the
air conditioner
to prevent
tripping
of the compressor
overload.
Airflow is restricted.
* Make sure there
are no curtains,
blinds or fi]rniture
blocking
the front of the air conditioner.
The temp control
may not
• On models
with touch pads: In COOL mode, press tim
be set correctly.
DECREASE•pad.
• On models
with control
knobs,
turn the temperature
knob to a higher
numbel:
The air Filter is dirty.
• Clean the filter at least every 30 days.
See tim Operating Instructions section.
The room may have been hot.
• When
the air conditioner
is first turned
on, you need to
allow time for the room
to cool down.
Cold air is escaping.
• Check for open fi]rnace
floor registers
and cold air returns.
• Set tim air conditioner's
vent to tim closed
position.
Cooling
coils have iced up.
• See "air conditioner
froozing up"
below.
Ice blocks
the air flow and
• On models
with control
knobs,
set the mode
control
at
stops the air conditioner
HIGH FAN or HIGH COOL with the temp at 1 or 2
from cooling
the room.
• On models
with touch pads, set the controls
at
HIGH (F3)FAN or HIGH (F3) COOLand set the thermostat
to a higher
temperature.
The batteries
are inserted
• Check
the position
of the batteries.
_i]ley should
be
incorrectly,
inserted
in the opposite
(+) and (-) direction.
The batteries
may be dead.
• Replace
tim batteries.
Excessively
hot and
• This is normal.
humid weather.
Wate_drip_indo_
The air conditioner
is not
____________________________________________________________________
tedto the ou ide
Moisture
is removed
from
indoor air and drains into
rear of a cabinet where a fan
blows it against the outdoor
condenser
coil.
• For pro[mr water disposal, make sure the air conditoner
slants slightly"fi'om the case fi'ont to tim rein:
• This is normal for a short period in areas with little
humidity; normal for a longer period in very humid areas.