Installation instructions
ADVANCE
PLANNING
Ductwork
Planning
. This hood
may be vented
vertically
through
upper
cabinets,
soffit or ceiling.
A duct
transition
piece
is
supplied
for vertical
exhaust.
Use locally supplied
elbows to vent horizontally
through
the rear
wall.
See page
13.
* Determine
the exact location
of the vent hood.
* Plan the route
for venting
exhaust
to the outdoors°
* Use the shortest
and
straightest
duct rotlte
possible.
For safisfhctory
peffbrmance,
duct run should
not
exceed
100 R. equivalent
length
for any duct
configurations.
* Refer to "Duct Fittings"
chart to compute
the maximum
permissible
length
for duct runs to the outdoors.
* Use metal
duct_,vork
only.
* A transition
piece
for 7" round
duct is supplied.
Use
7"
rotuxd
duct or you may use 3-1/4"
x 12" rectangular.
* Install
a wall cap or roof
cap with damper
at the
exterior
opening.
Order
the wall or roof cap and
any transition
needed
in advance.
Kit -JXDW1
Order kitJXDW1
if your installation
requires
horizon ml
ducfing
fi'om the top of the hood through
the back _vtll and:
* You have an 8 fL ceiling
and
need
to use aJXCH
Series
Chimney
Corm;
or
* You have a 12" cabinet
or 12" soffit that the hood
is to
be mounted
beneath.
This kit provides
a duct transition
fiom
7" round
to
3¼" x 10" rectangular
for through-the-wall
venting.
Wall Framing
for Adequate
Support
* This vent hood
is heavy. Adequate
structural
support
must be provided.
The
hood
must
be secured
to
vertical
studs
in the wall. See page
14.
* We strongly
recommend
that the vent hood
with
duct
cover be on site before
final f]aming
and
wall
finishing.
This will also help to accurately
locate
the
ductwork
and electrical
service.
DUCT FiTTiNGS
Follow
these
guidelines
fin proper
duct sizing in the
ducting
charts.
DUCTIN6 CHART- 30" Models
EquivalentLengthinFeet For7" RoundDuct
Z
0
25
50
75
100
125
150
E
>
600
500
400
300
200
7" Round90° Elbow= 14ft.
7" RoofCap= 39 ft.
MAXIMUM
DUCT LENGTH:
7" dia. duct should
not
exceed
100 equivalent
feet.
DECORATIVE
DUCT COVERS
A decorative
duct cover is available.
The duct cover
conceals
the ductwork
running
f?om
the top of the
hood
to the ceiling
or soffit. The duct cover will fit
8 R. to 10 R. ceiling
heights.
See page
12 for details.
POWER SUPPLY
IMPORTANT-
(Please
read carefully)
,&WARNING'.
FOR PERSONAL
SAFETY, THIS APPLIANCE
MUST
BE PROPERIX
GROU NDED.
Remove
house
fl_se or open
circuit
breaker
before
beginning
installation.
Do not use an extension
cord
or adapter
plug with
this appliance.
Follow National
Electrical
Code
or
prevailing
local codes
and
ordinances.
Electrical
supply
This vent hood
must
be supplied
with 120V, 60Hz, and
connected
to an individual,
properly
grounded
branch
circuit,
and protected
by a 15 or 20 amp circuit
breaker
or time delay fl_se.
* Wiring
must
be 2 wire with ground.
* If the electrical
supply
does not meet
the above
requirements,
call a licensed
electrician
before
proceeding.
* Route
house
wiring
as close to the installation
location
as possible
in the ceiling,
soffit or wall.
See page
13 for details.
* Connect
the wiring
to the house
wiring
in
accordance
with local
codes.
Grounding
instructions
The grounding
conductor
must
be connected
to a
grounded
metal,
permanent
wiring
system,
or an
equipment-grounding
terminal
or lead on the hood.
AWARNING"
[] The
improper
connection
of the equipment-grounding
conductor
can result
in a
risk of electric
shock.
Check
with a qualified
electrician
or service
representative
if you are in doubt
whether
the appliance
is properly
grounded.
9