Installation Instructions

Installing the ASR-ZW Receiver
The ASR-ZW receiver should be located as near as is practical to
the boiler or zone valve to be controlled, as well as a convenient
mains electricity supply. To remove the wall plate from the ASR-ZW,
undo the two retaining screws located on the underside, the wall
plate should now be easily removed. Once the wall plate has been
removed from the packaging please ensure the ASR-ZW is re-sealed
to prevent damage from dust, debris etc.
The wall plate should be fitted with the retaining screws located at
the bottom and in a position which allows a total clearance of at
least 50mm around the ASR-ZW receiver.
Direct Wall Mounting
Offer the plate to the wall in the position where the ASR-ZW is to be mounted and mark the fixing
positions through the slots in the wall plate. Drill and plug the wall, then secure the plate into
position. The slots in the wall plate will compensate for any misalignment of the fixings.
Wall Box Mounting
The wall plate may be fitted directly on to a single gang flush wiring box complying with BS4662,
using two M3.5 screws. The receiver is suitable for mounting on a flat surface only; it is not suitable
for mounting on an unearthed metal surface.