Advertisement

CWI = Cold Water inlet
D = Drain
EI = Electrical connection
Front
Top
G = Gas connection
Side
Natural Gas Combi Oven 61
Electric
Supply voltage:
267700(AOS061GTG1)
Circuit breaker required
Gas
ISO 7/1 gas connection diameter:
Natural gas:
Pressure:
Steam generator:
Heating elements:
Total thermal load:
Water:
Water inlet "CW" connection:
Water inlet "FCW" connection:
Total hardness:
Pressure:
Pressure:
Drain "D":
Electrolux recommends the use of treated water, based on
testing of specific water conditions.
Please refer to user manual for detailed water quality
information.
Installation:
Clearance:
Suggested clearance for service
access:
Capacity:
GN:
Max load capacity:
Key Information:
Net weight:
Shipping weight:
Shipping height:
Shipping width:
Shipping depth:
Shipping volume:
The company reserves the right to make modifications to the products
without prior notice. All information correct at time of printing.
air-o-steam
Touchline
230 V/1N ph/50/60 Hz
1/2" MNPT
7" w.c. (17.4 mbar)
10 kW
34090 BTU (10 kW)
57953 BTU (17 kW)
3/4"
3/4"
5-50 ppm
1.5-4.5 bar
15-36 psi (1.5-4.5 bar)
1"1/4
Clearance: 5 cm rear and right
hand sides.
50 cm left hand side.
6 - 1/1 Gastronorm
30 kg
146 kg
170 kg
1060 mm
990 mm
950 mm
1 m³
air-o-steam