PAC-2700 ELECTRIC COOLING FAN CONTOLLER PAC-2700 FAN CONTROLLER IMPORTANT NOTE: The +12V for the CUSTOM ADJUSTMENT controller should NOT be taken from the same circuit as the Fan Power 12V as this can cause the fan to cycle on and +12V with key ON off.
Page 2
If the gauge uses a two-wire temperature sender (such as Autometer full sweep) use of a dedicated Dakota Digital sender is required. If a gauge is not used, ONLY a Dakota Digital 300ºF sender should be used. Other senders may not give a correct reading to the control unit.
Page 3
Option No gauge, dedicated Dakota Digital sender only Dakota Digital individual temp gauge with sender Dakota Digital instrument cluster with control box (ver. STR-D or later, older versions use CUS) Stewart Warner gauge and sender Classic gauge and sender VDO gauge and sender...
Page 4
Custom Calibration Note 1: If your engine is warm you may need to disconnect the wire from your sender in order get to the lower points on the gauge. Note 2: If the key is turned off in custom setup, the previous gauge setting will be used and the custom gauge will not be saved.
Hold SW1, if temperature read is lower than expected or (gauge setup) doesn’t match gauge, redo setup. Wrong sender used For sender only applications ONLY a Dakota Digital (for no gauge setup) 300ºF sender can be used. Other senders may not give a correct temperature reading.
Any action for breach of any warranty hereunder, including any implied warranty of merchantability, must be brought within a period of 24 months from date of original purchase. No person or representative is authorized to assume, for Dakota Digital, any liability other than expressed herein in connection with the sale of this product.