Func.
Code
B095
Dynamic braking control
• 00 Disable
• 01 Enable during RUN only
• 02 Enable always
B096
Dynamic braking activation level
B098
• Thermistor for thermal protection control
• 00 Disable
• 01 Enable – PTC thermistor
• 02 Enable – NTC thermistor
B099
Thermal protection level setting
B100
Free-setting V/f frequency (1)
B101
Free-setting V/f voltage (1)
B102
Free-setting V/f frequency (2)
B103
Free-setting V/f voltage (2)
B104
Free-setting V/f frequency (3)
B105
Free-setting V/f voltage (3)
B106
Free-setting V/f frequency (4)
B107
Free-setting V/f voltage (4)
B108
Free-setting V/f frequency (5)
B109
Free-setting V/f voltage (5)
B110
Free-setting V/f frequency (6)
B111
Free-setting V/f voltage (6)
B112
Free-setting V/f frequency (7)
B113
Free-setting V/f voltage (7)
B120
Brake Control Enable
• 00 Disable
B121
Brake Wait Time for Release
B122
Brake Wait Time for Acceleration
B123
Brake Wait Time for Stopping
B124
Brake Wait Time for Confirmation
B125
Brake Release Frequency Setting
B126
Brake Release Current Setting
Name / Description
• 01 Enable
27
Default
Value
Value
–FE/FU/FR
00
360/
720
00
3000
0.
0.0
0.
0.0
0.
0.0
0.
0.0
0.
0.0
0.
0.0
0.
0.0
00
0.00
0.00
0.00
0.00
0.00
Rated
current of
each inverter
Set