Troubleshooting and Maintenance

This section provides details for L100-M Series error codes corresponding to Chapter 6,
"Troubleshooting and Maintenance," in the L100 Inverter Instruction Manual.
Error Codes
L100-M Series inverters have the additional error code listed below.
Error
Code
E 6 0
Communication error
Name
The RS422/485 serial cable may be disconnected
or have an open wire, short, etc.
The communication error may be due to the
external device. Check whether the interruption is
for more than 3 seconds before resetting the error.
If so, the watchdog timer in the inverter is timing
out due to no response from the external device.
L100-M Inverter
Cause(s)
29