Download Print this page

Mitsubishi FX2NC-ENET-ADP User Manual

Advertisement

Quick Links

FX
-ENET-ADP Ethernet adapter
2NC
USER'S MANUAL
Manual Number
JY997D12301
Revision
D
Date
May 2007
• This manual contains text, diagrams and explanations which guide the
reader in the correct installation and operation of the FX
-ENET-ADP
2NC
Ethernet adapter. It should be read and understood before attempting to use
the unit.
• If in doubt at any stage of the installation of FX
-ENET-ADP, consult a
2NC
professional electrical technician who is qualified and trained to the local
and national standards which apply to the installation site.
• If in doubt about the operation or use of the FX
-ENET-ADP, please
2NC
consult the nearest Mitsubishi Electric distributor.
• This manual is subject to change without notice.
• Microsoft
®
and Windows
®
are either registered trademarks or trademarks of
Microsoft Corporation in the United States and/or other countries.
• The company name and the product name described in this manual are the
registered trademarks or trademarks of each company.
Guideline for the safety of the user and protection of the FX
-ENET-ADP.
2NC
This manual provides usage information for the FX
-ENET-ADP Ethernet
2NC
adapter. The manual has been written to be used by trained and competent
personnel.
Notes on the symbols used in this manual
At various times throughout out this manual certain symbols will be used to
highlight points of information which are intended to ensure the users personal
safety and protect the integrity of equipment. Whenever any of the following
symbols are encountered, its associated note must be read and understood. Each
of the symbols used will now be listed with a brief description of its meaning.
Hardware Warnings
1) Indicates that the identified danger WILL cause physical and
property damage.
2) Indicates that the identified danger could POSSIBLY cause
physical and property damage.
3) Indicates a point of further interest or further explanation.
DISPOSAL PRECAUTIONS
• When disposing of this product, treat it as industrial waste.
INSTALLATION PRECAUTIONS
• Use the module in an environment that meets the general
specifications contained in this manual. Using this module in an
environment outside the range of the general specifications could
result in electric shock, fire, erroneous operation, and damage to or
deterioration of the product.
• Do not disassemble or modify the module. Doing so may cause
failure, malfunction, injury, or fire.
TRANSPORTATION AND MAINTENANCE PRECAUTIONS
• During transportation avoid any impact as the module is a precision
instrument. Doing so could cause trouble in the module.
• It is necessary to check the operation of module after transportation,
in case of any impact damage.
●Note Concerning the CE Marking●
The CE marking does not guarantee that an entire mechanical module produced in
accordance with the contents of the notification comply with the following standards.
Compliance to EMC standards of the entire mechanical module should be checked by
the user / manufacturer.
Standards with which this product complies
Type: Programmable Controller (Open Type Equipment)
Models: Products manufactured:
from April 1st, 2004 to April 30th, 2006 are compliant with
EN61000-6-4 and EN61131-2:1994+A11:1996+A12:2000 and EN61000-6-2
after May 1st, 2006 are compliant with EN61131-2:2003
Electromagnetic Compatibility
Remark
Standards (EMC)
EN61000-6-4:2001
Compliance with all relevant aspects of the
Electromagnetic compatibility
standard. (Radiated Emissions and Mains
-Generic standards - Emission standard
Terminal Voltage Emissions)
for Industrial environment
EN61131-2:1994/A11:1996/A12:2000
Compliance with all relevant aspects of the
Programmable controllers
standard. (RF Immunity, Fast transients,
-Equipment requirements and tests
ESD and Damped oscillatory wave)
Compliance with all relevant aspects of the
EN61000-6-2:2001
standard. (RF immunity, Fast transients,
Electromagnetic compatibility
ESD, Conducted, Surges, Power
-Generic standards Immunity for
magnetic fields, Voltage dips and Voltage
industrial environments.
interruptions)
Compliance with all relevant aspects of the
standard.
EN61131-2: 2003
(Radiated Emissions, Mains Terminal
Programmable controllers
Voltage Emissions, RF immunity, Fast
-Equipment requirements and tests
Transients, ESD, Surge, Voltage drops
and interruptions, Conducted and Power
magnetic fields)
For more details please contact the local Mitsubishi Electric sales site.
- Notes for compliance to the EMC regulation.
It is necessary to install the FX
2NC
-ENET-ADP module in a shielded metal control
panel.
1. Associated Manuals
Manual name
Manual No.
Description
FX
1S
HARDWARE MANUAL
JY992D83901
FX
HARDWARE MANUAL
JY992D89301
1N
Describes the hardware of the
F X S e r i e s P L C s u c h a s
FX
HARDWARE MANUAL
JY992D66301
2N
s p ec i f i c at i on s , w i r i ng , an d
FX
HARDWARE MANUAL
2NC
installation.
JY992D76401
(DSS/DS)
JY992D87201
(D/UL)
D es c r i be s th e i ns t r uc ti o ns
FX PROGRAMMING MANUAL II
JY992D88101
available in the FX
FX
/FX
Series PLC.
2N
2NC
Describes operation details of
FX Configurator-EN
JY997D20501
FX Configurator-EN
OPERATION MANUAL
Configuration Software.
FX
-CNV-BD Special Adapter
1N
JY992D84701
Connection Board
Describes matters related to the
installation of the boards.
FX
-CNV-BD Special Adapter
2N
JY992D63601
Connection Board
For GX Developer and MX Component, refer to the operation manual respectively.
2. Outline of Product
The FX
2NC
-ENET-ADP is an Ethernet adapter of 10BASE-T specifications for the
FX
, FX
, FX
and FX
Series.
1S
1N
2N
2NC
The FX
-ENET-ADP enables the upload, download, monitor, and test of a program
2NC
from the personal computer (GX Developer or MX Component) via Ethernet.
3. Installation
Caution
• Use only in the environments specified under the general specifications
in the manual.
Do not use the product in environments with excessive or conductive
dust, corrosive (including salt breeze, Cl
2
, H
2
S, SO
flammable gas, oily smoke, moisture or rain, excessive heat, regular
impact shocks or excessive vibration, as it may result in electrical shock,
fire, malfunction, damage or deterioration of the product.
• Make sure to shut off the external power before installing or wiring it.
Electric shock or serious damage to the product may occur, if the external
power is not disconnected.
• Never drop wire chips or shavings into the ventilation slits when drilling
screw holes or performing wiring, as they may cause fire, breakdown, or
malfunction.
• Securely install the FX
-ENET-ADP to the designated port.
2NC
A poor connection may result in malfunction.
3.1 How to Install to FX Series PLC
Installation to FX
/FX
/FX
1S
1N
2N
Turn OFF the PLC before beginning any
work.
1) Remove the panel cover from the top
face of the main unit.
2) Take off the resin cover from the left
side of the main unit.
3) Install the following board to the port
on the main unit.
Corresponding
Board name
model
FX
-CNV-BD
FX
/FX
1N
1S
1N
FX
2N
-CNV-BD
FX
2N
4) Affix the above board using the
supplied M3 screws.
Tightening torque: 0.3 to 0.6 N·m
5) Connect the built-in cable of the
FX
2NC
-ENET-ADP to the port on the left side of the board.
Installation to FX
2NC
Turn OFF the PLC before beginning any work.
1) Remove the cover from the special adapter port provided on the left side of the
main unit.
2) Connect the built-in cable of the FX
2NC
-ENET-ADP to the special adapter port.
3.2 Installation to a Panel Face
Direct installation to the panel face
Directly attach to the panel face using 2 sets of a
screw (M4), a spring washer, and a flat washer
in the mounting holes.
Tightening torque: 0.7 to 1.0 N·m
For the pitch and positions of mounting screw
holes, refer to the external dimensions.
Mounting on DIN rail
Affix the FX
-ENET-ADP to the DIN rail,
2NC
DIN46277 (35 mm (1.37") wide).
1S
/FX
1N
/
Dismounting from DIN rail
Slightly pull down the DIN rail mounting clip
using a tool such as a slotted screwdriver. Pull
down the clip further, and the rail will be locked
with the clip left open.
4. System Configuration
FX
2NC
-ENET-ADP
PC
FX
,FX
,FX
FX
1S
1N
2N
2NC
LAN
cables
HUB
2
, NO
2
, etc.) or
LAN cables
PLC
Ethernet adapter
FX
1S
/FX
1N
PLC + FX
1N
-CNV-BD
FX
PLC + FX
-CNV-BD
FX
-ENET-ADP
2N
2N
2NC
FX
PLC
2NC
• Applicable version of GX Developer/MX Component
Software
Applicable Version
Installation to
FX
/FX
/FX
1)
1S
1N
2N
GX Developer
Ver. 8.12N or later
MX Component
Ver. 3.05F or later
4)
3)
5. Product Specification
5)
5.1 Specifications
2)
The general specifications of FX
Series PLC except the following items.
Item
1)
Withstand voltage
Installation to
2)
General
FX
2NC
specifications
Insulation resistance
Power supply
Supply voltage/
specifications
current
Baud rate
Protocol
Performance
Transmission media
specifications
Topology
Communication
FX Series
PLC
method
To Ethernet
Connector
To ground
ENET
-ADP
Mass
Screws
5.2 Outside dimensions and name of each part
16.1(0.64")
(to screw holes)
2-φ4.2(0.17")
2) 3)
DIN rail
FX
2NC
-ENET-ADP
POWER
ENET
FX Series
LINK
1)
PLC
ACT
-ADP
SD
RD
To lock the tab
1)
Detach
19.1
10)
(0.76")
. . . .
1) Mounting hole (2-φ4.2)
Used when FX
-ENET-ADP is mounted directly.
2NC
Not used when the module is mounted on DIN rail.
2) POWER LED (green)
Lit while 5V DC power is supplied from the PLC.
3) LINK LED (green)
Lit while the HUB is connected by an RJ45 connector and the power is on.
LAN cable
4) ACT LED (red)
Lit while transferring data with connected Ethernet.
Twisted pair cable
5) SD LED (red)
Category 5(e) STP or 3
Lit while sending data to the connected PLC.
STP (straight cable)
6) RD LED (red)
Lit while receiving data from the connected PLC.
7) Connecting cable
Used to connect the main unit.
8) RJ45 connector
Connects the Ethernet cable.
With FX Configurator-EN
Ver. 8.25B or later
Ver. 3.08J or later
-ENET-ADP are same as those of the FX
2NC
Description
5 0 0 V A C f o r 1
Conforms to JEM-
min
1021, between all
terminals together
5 MΩ or more by
and grounding
500V DC megger
terminal
5V DC, 135 mA (supplied from PLC)
10Mbps
CSMA/CD(IEEE802.3)
10BASE-T
Star type
Full duplex
RJ45 connector
3 pins
(However, internally short-circuited)
0.1 kg (0.22 lbs)
Unit: mm (inches)
4)
5)
7)
6)
11)
8)
9)
7(0.28")
(Height of screw hole)
74(2.92")
78(3.08")

Advertisement

loading

Summary of Contents for Mitsubishi FX2NC-ENET-ADP

  • Page 1 Star type • The company name and the product name described in this manual are the For more details please contact the local Mitsubishi Electric sales site. registered trademarks or trademarks of each company. 3.2 Installation to a Panel Face Communication - Notes for compliance to the EMC regulation.
  • Page 2 9) Terminal block for grounding 7. Parameter Settings for FX -ENET-ADP 7.2 Parameter setting methods When file registers are used to set the Ethernet parameters Internally short-circuited. Select [Parameter] - [PLC parameter] - [Memory capacity] in GX Developer, and To connect the FX -ENET-ADP to the Ethernet, it is necessary to set the Ethernet Set the Ethernet parameters using either of the following methods through serial Applicable cable: AWG 17 to 14...
  • Page 3 8. Settings in GX Developer 9. Setting in MX Component First, set "Ethernet board" at [PC Set the IP address, the TCP port number and the connection route, etc. on the Note: side I/F]. Next, set "FX-ENET Transfer setup dialog box, when accessing FX , FX , FX , or FX...
  • Page 4: 10. Troubleshooting

    This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.
  • Page 5 Star type • The company name and the product name described in this manual are the For more details please contact the local Mitsubishi Electric sales site. registered trademarks or trademarks of each company. 3.2 Installation to a Panel Face - Notes for compliance to the EMC regulation.
  • Page 6 This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.