Charging:
The battery
is rated at 14AH (ampere-hour).
10% of the ampere-
hour rating should be used as the charging current.
A battery charger
should be used that can be adjusted to deliver 1.4 amps.
The battery
gives off expiosive
hydrogen
gas during normal opera-
tion.
A spark
or open flame
can cause the battery
to explode
with
enough force to kill or seriously
hurt you.
Keep sparks
and flames
away.
Wear protective
clothing
and a
face shield,
or have a skilled
mechanic
do battery
maintenance.
1. Remove the battery cell caps.
2. Connect the battery charger following
the manufacturer's
instruc-
tions.
3. Charge the battery 3-4
hours.
4. After the battery is charged,
inspect the electrolyte
level in each of
the cells. Add distilled water as necessary.
5. Install the battery caps.
6. Clean the outside of the battery and the battery tray with a solution
of baking soda and water.
Installation:
1. Install the battery in the generator.
2. Install the positive
(+) cable to the battery positive
(+) terminal;
then install the negative
(-)
cable to the battery
negative
(-)
terminal.
3. Install the battery set plate.
50
',