Electric Supply; Gas Supply - Maytag MGR4452BDB - 4.5 GAS RANGES Installation Manual

Gas 30-inch wide free-standing range
Hide thumbs Also See for MGR4452BDB - 4.5 GAS RANGES:
Table of Contents

Advertisement

CONNECTING
THE RANGE
ELECTRIC
SUPPLY
The appliance,
when installed,
must be electrically
grounded
in accordance
with local codes
or, in the
absence
of local codes,
with the National
Electrical
Code,
ANSI/NFPA
70.
In Canada
the range must be installed
in accordance
with
the current
CSA Standard
C22.1 - Canadian
Electrical
Code Part 1.
ELECTRICAL
SUPPLY
CONNECTION:
The range requires 120 volts, 60 cycle alternating current
from an outlet. See serial plate for rating.
User may experience
occasional
circuit tripping
if Ground
Fault Circuit
Interrupter
(GFCI)
outlet or breaker
is in use.
, WARNING
Electrical
Grounding
Instructions
This appliance
is equipped
with a (three-prong)
grounding
plug for your protection
against shock
hazard
and
should
be
plugged
directly
into a
properly grounded receptacle.
Do not cut or remove
the grounding prong from this plug.
, WARNING
DISCONNECT
ELECTRICAL
SUPPLY
BEFORE
SERVICING
THE APPLIANCE.
GAS SUPPLY
Installation
of this range must conform
with local codes
or,
in the absence
of local codes,
with the National
Fuel Gas
Code, ANSI Z223.1-1atest
edition.
In Canada
the range must be installed
in accordance
with
the current
CGA Standard
CAN/CGA-B149
- Installation
Codes for Gas Burning
Appliances
and Equipment
and/or
local codes.
GAS
SUPPLY
CONNECTION:
(See figure 4)
A QUALIFIED SERVICEMAN
OR GAS APPLIANCE
INSTALLER
MUST MAKE THE GAS SUPPLY
CONNECTION.
Leak testing
of the appliance shall be
conducted by the installer according
to the
instructions
given in section h.
NATURAL
GAS SUPPLY
LINE MUST HAVE A NATURAL
GAS SERVICE
REGULATOR.
INLET PRESSURE
TO
THIS APPLIANCE
SHOULD
BE REDUCED
TO A
MAXIMUM
OF 14 INCHES
WATER
COLUMN
(0.5
POUNDS
PER SQUARE
INCH (P.S.I.) LIQUEFIED
PETROLEUM
(L.P.)/PROPANE
GAS SUPPLY
LINE
MUST HAVE A L.P. GAS PRESSURE
REGULATOR.
INLET PRESSURE
TO THIS APPLIANCE
SHOULD
BE
REDUCED
TO A MAXIMUM
OF 14 INCHES
WATER
COLUMN
(0.5 P.S.I.).
INLET
PRESSURES
IN EXCESS
OF 0.5 P.S.I. CAN DAMAGE
THE APPLIANCE
PRESSURE
REGULATOR
AND OTHER
GAS
COMPONENTS
IN THIS APPLIANCE
AND CAN
RESULT
IN A GAS LEAK.
a.
A GAS CUTOFF
VALVE SHOULD
BE PUT IN AN
ACCESSIBLE
LOCATION
IN THE SUPPLY
LINE
AHEAD
OF THE RANGE,
FOR TURNING
ON AND
TURNING
OFF GAS SUPPLY.
If range is to be
connected
to house piping with flexible
or semi-rigid
metal connectors
for gas appliances,
CONNECTOR
NUTS MUST NOT BE CONNECTED
DIRECTLY
TO
PIPE THREADS.
THE CONNECTORS
MUST BE
INSTALLED
WITH ADAPTORS
PROVIDED
WITH
THE CONNECTOR.
b.
C.
d.
e.
f.
The house piping and/or range connector
used to
connect
the range to the main gas supply
must be
clean, free of metal shavings,
rust, dirt and liquids (oil
or water).
Dirt, etc. in the supply
lines can work its
way into the range manifold
and in turn cause failure
of the gas valves
or controls
and clog burners
and/or
pilot orifices.
CAUTION: DO NOT LIFT OR MOVE RANGE BY
DOOR HANDLES, OR BACKGUARD.
Turn off all pilots and main gas valve of other gas
appliances.
Turn off main gas valve at meter.
Before
connecting
range, apply pipe thread
compound
approved
for LPG to all threads.
Connect
range to gas supply
at appliance
pressure
regulator
using adaptors
supplied
with flexible
connector.
Rigid pipe may also be used. See rating
plate for type of gas range has been manufactured
for.
g.
Turn on main gas valve at meter, and relight pilots at
other gas appliances.
-5-