Pqa Diagnostic Program Error Code And Messages - Acer 710TE - Extensa - PII 233 MHz Service Manual

Service guide
Table of Contents

Advertisement

The right corner screen information gives you the available function keys and
the specified test number.
• Space
Enables/disables the item
• ESC
Exits the program
• F1
Help
• F2
Tests the selected item(s)
• Enter
Opens the available suboptions
• Test Times Indicates the number of tests to perform.
Note: The F1 and F2 keys function only after you finish configuring the
Test option.

PQA Diagnostic Program Error Code and Messages

\
Error Code
Message
System
16XX
Backup battery error
1XXX
CPU or Main board error
2XXX
Memory error
3XXX
Keyboard error
4XXX
Video error
5XXX
Parallel Port error
6XXX
Serial port or Main board
error
7XXX
Diskette drive error
8XXX
Hard disk error
9XXX
CD-ROM error
10XXX
CPU or Main board error
11XXX
Pointing device error
4-18
Spare Part/Action in Sequence
Backup battery
1. Reload BIOS default setting.
2. CPU
3. Main board
1. Reseat CPU(IMM module)
2. DIMM
3. Main board
1. Reseat Keyboard
2. Keyboard
3. Main board
1. Main board
1. Main board
1. Main board
1. Diskette drive
2. Main board
1. Reload BIOS default setting.
2. Hard disk
3. Main board
1. Reseat CD-ROM cable
2. CD-ROM drive
3. Main board
1. CPU
2. Main board
1. Reseat Keyboard
2. Keyboard
3. Main board