Any number of E_Ports in a fabric can be configured for gateway links, provided the following rules
are followed:
All switches in the fabric must be upgraded to Fabric OS 5.2.0 or later.
All switches in the fabric are using the core PID format.
The switches connected to both sides of the gateway are included when determining switch count
maximums.
Extended links (those created using the Extended Fabrics licensed feature) and the security features if
you are running a Fabric OS version earlier than 6.x in Secure Fabric OS are not supported through
gateway links.
To configure a link through a gateway:
1.
If you are not sure if the PID format is consistent across the entire fabric, enter the configShow
command on all switches to check the PID setting. If necessary, change the PID format on any
nonconforming switches, as described in
2.
Connect to the switch on one end of the gateway and log in using an admin account.
3.
Enter the portCfgIslMode command that is appropriate for your hardware model:
4/8 SAN Switch and 4/16 SAN Switch, 8/8 SAN Switch, 8/24 SAN Switch, 8/40 SAN Switch,
8/80 SAN Switch, Brocade 4Gb SAN Switch for HP p-Class BladeSystem, Brocade 4Gb SAN Switch
for HP c-Class BladeSystem, SAN Switch 4/32, 4/64 SAN Switch, SAN Switch 4/32B, 400
Multi-protocol Router, 4/256 SAN Director and DC SAN Backbone Director:
portCfgIslMode <port, mode>
Specify a port number. Valid values for port number vary depending on the switch type. The mode
operand is required: specify 1 to enable ISL R_RDY mode (gateway link) or specify 0 to disable it.
4/256 SAN Director and DC SAN Backbone Director (short name, DC Director):
portCfgIslMode <slot/port, mode>
Specify a slot/port number pair. Valid values for slot and port number vary depending on the switch
type. The mode operand is required: specify 1 to enable ISL R_RDY mode (gateway link) or specify 0 to
disable it.
In the following example, slot 2, port 3 is enabled for a gateway link:
switch:admin> portcfgislmode 2/3, 1
Committing configuration...done.
ISL R_RDY Mode is enabled for port 3. Please make sure the PID
formats are consistent across the entire fabric.
switch:admin>
4.
Repeat the steps for any additional ports that will be connected to the gateway.
5.
Repeat the procedure on the switch at the other end of the gateway.

Checking switch status

This section describes how to verify:

Switch operation

High availability features
Fabric connectivity
Device connectivity
Display switches in Access Gateway mode
Switch operation
To check switch operation:
1.
Connect to the switch and log in using an admin account.
2.
Enter the switchShow command. This command displays a switch summary and a port summary.
3.
Check that the switch and ports are online.
46
Standard features
"Configuring the PID
format" on page 463.