1.
When the Fault Management display is active (flashing), press
menu.
The LTEA selection menu is active (LTEA 0 is displayed).
2.
Press
3.
Press
to observe data about the selected error.

Interpreting fault management information

Each version of HP P6000 Command View includes an ASCII text file that defines all the codes
that the authorized service representative can view either on the GUI or on the OCP.
IMPORTANT:
The file name identifies the controller model, file type, XCS baselevel id, and XCS version. For
example, the file name hsv210_event_cr08d3_5020.txt provides the following information:
hsv210_—The EVA controller model number
event_—The type of information in the file
w010605_—The base level build string (the file creation date).
01—The creation year
06—The creation month
05—The creation date
5020—The XCS version
Table 21 (page 105)
Table 22 Controller event text description file
Information type
Event Code
Termination Code (TC)
Coupled Crash Control Codes
Dump/Restart Control Codes
Corrective Action Codes (CAC)
Software Component ID Codes
(SWCID)
Event Information Packets (EIP)
or
to increment to a specific error.
This information is for the exclusive use of the authorized service representative.
describes types of information available in this file.
This hexadecimal code identifies the reported event type.
This hexadecimal code specifies the condition that generated the termination
code. It might also define either a system or user initiated corrective action.
This single digit, decimal character defines the requirement for the other controller
to initiate a coupled crash control.0. Other controller SHOULD NOT complete
a coupled crash.1. Other controller SHOULD complete a coupled crash.
This single decimal character (0, 1, 3) defines the requirement to:0. Perform a
crash dump and then restart the controller.1. DO NOT perform a crash dump;
just restart the controller.3. DO NOT perform a crash dump; DO NOT restart
the controller.
These hexadecimal codes supplement the Termination Code information to
identify the faulty element and the recommended corrective action.
These decimal codes identify software associated with the event.
These codes specify the packet organization for specific type events.
to select the Detail View