Level and Position Range- Level range by adjusting the
(4) leveling legs with a wrench. Note: A minimum clearance
of 1/8" is required between the bottom of the range and the
leveling leg to allow room for the bracket. Use a spirit level
to check your adjustments. Slide range back intoposition.
Visually check that rear leveling leg is inserted into and
fully secured by the Anti-Tip Bracket by removing lower
panel or storage drawer. For models with a warmer drawer
or broiler compartment,
grasp the top rear edge of the
range and carefully attempt to tilt it forward.
4.
Connect
the range to the gas supply.
NOTE: To prevent leaks use pipe joint sealant on all male
(outside) pipe threads.
*Please note:
Models without
self-cleaning
feature may
have an
additional 4 to
7 inches
clearance from
the floor.
Fig. 4a
Centerline
of range
I
I
!
--_111-1/2"
_,--i
_
|
Recommended
area fe d
i
I
i i
120V outlet on rear of |
--,-....... J.....
/
wall and area for thru / i
_q__::-
:- :;:1
Ii
the wall connection
of|
'
,
23"
',
i_
.
I
I
__
ptpe stub and shut'°ff
/
I
_
va ves
shaded area |
5"
J
,
;
i
for thru'_
_ _
Edge
I
the floor connection
of
pipe stub and shut-off
valve.J
2. Provide an adequate
gas supply.
This unit is pre-set to operate on 4" natural gas manifold
pressure. A convertible pressu re regulator is connected to the
manifold and MUST be connected in series with the gas supply
line. If the LP/Propane conversion kit has been used, follow
instructions provided with the kit for converting the pressure
regulator to LP/Propane use. The LP kit can be found on the
back side of the range (some models).
Care must be taken during installation of range not to obstruct
the flow of combustion and ventilation air.
For proper operation, the maximum inlet pressure to the
regulator should be no more than 14 inches of water column
pressure. The inlet pressure to the regulator must be at least
1 inch greater than regulator manifold pressure. Examples: If
regulator is set for natural gas 4 inch manifold pressure, inlet
pressure must be at least 5 inches; if regulator has been
converted for LP/Propane gas 10 inch manifold pressure, inlet
pressure must be at least 11 inches.
Leak testing of the appliance shall be conducted according to
the instructions in step 4g.
The gas supply line should be 1/2" or 3/4" I.D.
3. Seal wall openings.
Seal any openings in thewall behind the range and in thefloor
under the range after gas supply line is installed.
Manual
Flare
Flexible
Flare Union
Pressure
Shutoff
Union
Appliance
Adaptor
Regulator
Valve
/
Conduit
/
off
Service Shut-Off Valve Electric Ignition models onl
_''_'4'_m_ _ ,nly___x
(Shown in ON Position).
Be sure lever is in the "On" position when
installation is complete
Fig. 4b
_..__J_Gas
Shut-Off Valve