Summary of Contents for NETGEAR GSM7224v2 - Layer 2 Managed Gigabit Switch
Page 1
Managed Layer 2 Switches GSM7224 and GSM7248 Hardware Installation Guide NETGEAR, Inc. 350 E. Plumeria Drive Sant Jose, CA 95134 USA 202-10351-02 July 2009...
In the interest of improving internal design, operational function, and/or reliability, NETGEAR reserves the right to make changes to the products described in this document without notice. NETGEAR does not assume any liability that may occur due to the use or application of the product(s) or circuit layout(s) described herein.
Page 3
EN 55 022 Declaration of Conformance This is to certify that the NETGEAR ProSafe™ 24-Port L2 Managed Switch with Static Routing GSM7224 is shielded against the generation of radio interference in accordance with the application of Council Directive 89/336/EEC, Article 4a.
Page 4
This is to certify that the NETGEAR ProSafe™ 48-Port L2 Managed Switch with Static Routing GSM7248 is shielded against the generation of radio interference in accordance with the application of Council Directive 89/336/EEC, Article 4a. Conformity is declared by the application of EN 55 022 Class A (CISPR 22) and EN 55 024.
Contents About This Manual Conventions, Formats, and Scope ...................vii How to Print This Manual ....................viii Chapter 1 Introduction GSM7224 Front Panel and LEDs ...................1-1 GSM7224 Rear Panel ....................1-2 GSM7248 Front Panel and LEDs ...................1-2 GSM7248 Rear Panel ....................1-3 Interpreting the LEDs ......................1-3 Safety Instructions ......................1-4 Chapter 2 Hardware Installation...
Page 6
Additional Troubleshooting Suggestions ...............3-2 Appendix A Default Settings and Technical Specifications Default Settings ......................A-1 Technical Specifications ....................A-3 Appendix B Related Documents v1.0, July 2009...
About This Manual The NETGEAR ® Managed Layer 2 Switches GSM7224 and GSM7248 Hardware Installation Guide describes how to install, configure, and troubleshoot the ProSafe™ 24-Port L2 Managed Switch with Static Routing GSM7224 and the ProSafe™ 48-Port L2 Managed Switch with Static Routing GSM7248.
NETGEAR website in Appendix B, “Related Documents”. Note: Product updates are available on the NETGEAR, Inc. website at http://kbserver.netgear.com/support. How to Print This Manual To print this manual, you can choose one of the following options, according to your needs.
Page 9
Managed Layer 2 Switches GSM7224 and GSM7248 Hardware Installation Guide • Click the print icon in the upper left of your browser window. Tip: If your printer supports printing two pages on a single sheet of paper, you can save paper and printer ink by selecting this feature. v1.0, July 2009...
Page 10
Managed Layer 2 Switches GSM7224 and GSM7248 Hardware Installation Guide v1.0, July 2009...
Managed Switch with Static Routing GSM7224 and ProSafe™ 48-Port L2 Managed Switch with Static Routing GSM7248. These switches can be free standing, or rack mounted in a wiring closet or an equipment room. For information about features for these products, see the NETGEAR website at http://www.netgear.com. GSM7224 Front Panel and LEDs The following figure shows the front panel of the GSM7224.
Managed Layer 2 Switches GSM7224 and GSM7248 Hardware Installation Guide GSM7224 Rear Panel The rear panel has a console port, a redundant power supply connector, and a standard AC power receptacle for the supplied power cord. Power receptacle Console Redundant power supply connector Figure 1-2...
Managed Layer 2 Switches GSM7224 and GSM7248 Hardware Installation Guide GSM7248 Rear Panel The rear panel has a console port, a redundant power supply connector, and a standard AC power receptacle for the supplied power cord. Console Redundant Power receptacle power supply connector Figure 1-4...
Managed Layer 2 Switches GSM7224 and GSM7248 Hardware Installation Guide Table 1-1. LED Descriptions (continued) Description 10/100/1000M SPD/Link/ACT LED Ports • Off. No link is established on the port. (1 LED per port) • Solid green. A valid 1000 Mbps link is established on the port. •...
Page 15
Managed Layer 2 Switches GSM7224 and GSM7248 Hardware Installation Guide – The product does not operate correctly when you follow the operating instructions. • Keep your system away from radiators and heat sources. Also, do not block cooling vents. • Do not spill food or liquids on your system components, and never operate the product in a wet environment.
Page 16
Managed Layer 2 Switches GSM7224 and GSM7248 Hardware Installation Guide • To help protect your system from sudden, transient increases and decreases in electrical power, use a surge suppressor, line conditioner, or uninterruptible power supply (UPS). • Position system cables and power cables carefully; route cables so that they cannot be stepped on or tripped over.
– Configuration software – Documentation including the ProSafe 7200R Managed Switches CLI Reference Manual, the ProSafe 7000 Series Managed Switch Administration Guide, the NETGEAR 7000 Series Managed Switches (7200RS, 7200, 7300S, 726), and this guide • Warranty and Support card •...
4. Make sure that all items are present. See “Package Contents” on page 2-1. Note: If any item is found missing or damaged, contact your local NETGEAR reseller for replacement. 5. Inspect the products and accessories for damage. Report any damage immediately.
Managed Layer 2 Switches GSM7224 and GSM7248 Hardware Installation Guide Installation Install the equipment in the following sequence, as presented in this chapter: 1. Select a location. See the following section, “Selecting a Location.” 2. Install the switch. See “Installing the Switch” on page 2-4.
Managed Layer 2 Switches GSM7224 and GSM7248 Hardware Installation Guide Table 2-1. Site Requirements for Switch Location (continued) Requirements Ventilation Do not restrict airflow by covering or obstructing air inlets on the sides of the switch. Keep at least 2 inches (5.08 centimeters) free on all sides for cooling. Be sure that there is adequate airflow in the room or wiring closet where you will install the switch.
Managed Layer 2 Switches GSM7224 and GSM7248 Hardware Installation Guide 3. Tighten the screws with a No. 1 Phillips screwdriver to secure each bracket. 4. Align the bracket and rack holes. Use two pan-head screws with nylon washers to fasten each bracket to the rack.
Managed Layer 2 Switches GSM7224 and GSM7248 Hardware Installation Guide SFP Modules The module bay accommodates a standard SFP module with an LC connector that is compatible with the IEEE 802.3z 1000BASE-X standard. SFP modules are sold separately. To install an SFP module insert the SFP module into the module bay. Press firmly to ensure that the module seats into the connector.
If you would like to purchase a RPS unit that is compatible with this switch, please go to the NETGEAR product support website http://www.kbserver.com. Select your product in the Product Support section of the screen. When the product support screen displays, look for the Certified RPS Power Supplier link.
Page 24
Managed Layer 2 Switches GSM7224 and GSM7248 Hardware Installation Guide To connect a console to the switch: 1. Connect the null-modem cable to the console port on the rear of the switch. Console port Figure 2-4 2. Connect the other end of the cable to a workstation or terminal. 3.
Chapter 3 Troubleshooting Troubleshooting Chart The following table lists symptoms, causes, and solutions of possible problems. Table 3-1. Troubleshooting Chart Problem Cause Solution Power LED is off. No power is received Check the power cord connections for the switch at the switch and the connected device.
You can verify the integrity of the switch by resetting the switch. To reset the switch, use the Tools > Reset command, or remove AC power from the switch and then reapply AC power. If the problem continues, contact NETGEAR Technical Support. •...
Appendix A Default Settings and Technical Specifications This appendix provides the default settings and technical specifications for the ProSafe™ 24-Port L2 Managed Switch with Static Routing GSM7224 and ProSafe™ 48-Port L2 Managed Switch with Static Routing GSM7248. Default Settings The following table lists the factory default settings for the switches. You can use the RST (reset) button to return a switch to its factory default settings.
Page 28
Managed Layer 2 Switches GSM7224 and GSM7248 Hardware Installation Guide Table A-1. Default Configuration Settings (continued) Features GSM7224 Default Settings GSM7248 Default Settings Admin edge port Enabled Enabled Link aggregation Disabled Disabled Port mirroring Disabled Disabled Traffic prioritization Disabled Disabled Disabled Disabled GVRP...
Page 31
Managed Layer 2 Switches GSM7224 and GSM7248 Hardware Installation Guide Table A-2. Technical Specifications (continued) Feature GSM7224 GSM7248 Environment Operating: Operating: • Temperature: 32° to 131°F (0° to 55°C) • Temperature: 32° to 131°F (0° to 55°C) • Humidity: 90% maximum relative •...
Page 32
Managed Layer 2 Switches GSM7224 and GSM7248 Hardware Installation Guide Default Settings and Technical Specifications v1.0, July 2009...
Page 33
Appendix B Related Documents This appendix provides links to reference documents you can use to gain a more complete understanding of the technologies used in your NETGEAR product. Document Link Windows XP and Vista Wireless http://documentation.netgear.com/reference/enu/winzerocfg/index.htm Configuration Utilities Internet Networking and TCP/IP http://documentation.netgear.com/reference/enu/tcpip/index.htm...
Page 34
Managed Layer 2 Switches GSM7224 and GSM7248 Hardware Installation Guide Related Documents v1.0, July 2009...