The faceplate timer (PWA) computer has a self-diag-
nostic function for the electrical system, except put
power and water meter. The computer monitors elec-
tronic components and circuits for correct operation. If a
malfunction occurs, an error code appears in the face-
plate display.
The chart below shows the error codes that could
appear, and the possible defects for each code.
CODE
MOST LIKELY
Err1, Err3, Err4
motor inoperative / wiring harness or connection to switch / position switch . valve defect causing high torque
Err5
faceplate timer (PWA)
While an error code appears in the display, all face
plate buttons are inoperable except the SELECT1 but-
ton. SELECT1 remains operational so the service per-
son can make the MANUAL INITIATED ELECTRONIC
DIAGNOSTICS (below) to further isolate the defect, and
check the water meter.
PROCEDURE FOR REMOVING ERROR CODE
FROM FACEPLATE:
• Unplug transformer from outlet.
• Correct defect
• Plug in transformer.
• Wait for 8 minutes.
The error code will return if the defect was not corrected.
MANUAL INITIATED ELECTRONICS DIAGNOSTICS:
To enter diagnostics, press the SELECT1 button and
hold for three seconds. The display will show valve
cycle position, position switch status (open or closed),
and turbine operation. See Fig. 59.
TURBINE OPERATION: If no water is flowing through
the softener, the turbine indicator displays three zeros.
When water is flowing, the flow bar scrolls across the
display, and a 000 to 140 count repeats for each gallon
of water passing through the turbine. To check for posi-
tive operation of the turbine if zeros are shown, open a
nearby soft water faucet and observe the turbine count
and flow bar. If you don't get a reading in the display,
with faucet open, pull the sensor from the valve outlet
port. Pass a small magnet back and forth in front of the
sensor. You should get a reading in the display. If you
get a reading, unhook the in and out plumbing and
check the turbine for binding.
POSITION SWITCH STATUS: With the valve in service,
or any of the recharge cycles, the switch indicator will
show open, while the valve is rotating from one position
to another, the indicator will show the switch closed. A
defect is probable if indications vary from this pattern.
36
Service Tech Information
Questions? Call The Kenmore Water Line 1-800-426-9345
SALT
SIGNAL
LEVEL
LEVEL
8
7
6
5
4
3
2
1
POSSIBLE DEFECT
valve position indicator
SALT
SIGNAL
LEVEL
LEVEL
8
7
6
5
4
3
2
1
position switch
indicator (open)
VALVE IN SERVICE POSITION
valve position indicator
SALT
SIGNAL
LEVEL
LEVEL
8
7
6
5
4
3
2
1
position switch
indicator (open)
VALVE IN RECHARGE POSITION (FILL, IN THIS EXAMPLE)
SALT
SIGNAL
LEVEL
LEVEL
8
7
6
5
4
3
2
1
position switch
indicator (closed)
VALVE ROTATING FROM ONE RECHARGE POSITION TO ANOTHER
(FROM FILL TO BRINEING IN THIS EXAMPLE)
LESS LIKELY
number of days
since the last
regeneration
SERV
DAY
water meter
turbine count
FLOW RATE
minutes of fill
cycle remaining
FILL
TIME REMAINING
water meter
turbine count
FLOW RATE
valve position indicator
(Fill and Brine Flashing)
minutes of brining
time (begins to count
FILL
down when valve
BRINE
reaches brining
TIME REMAINING
position)
water meter
FLOW RATE
turbine count
FIG. 60
FIG. 61