PROJECTOR SETUP menu
Navigating through the MENU ( page 29), select
PROJECTOR SETUP from the main menu and
then select the required item from the sub-menu.
Remote control
STATUS
You can check the using status of the projector.
SIGNAL
NAME: Name of input signal
FREQUENCY: Scanning frequency of input
signal
RUNTIME
PROJECTOR: Display current usage time of
projector
LAMP: Display current usage time of lamp
If no image signal is input for the time set with the
timer, the projector will enter into standby mode
automatically.
Change setting
DISABLE
Timer can be set in intervals of 5
15 - 60 MIN.
minutes
Control panel
Change setting
is disabled
PROJECTOR SETUP menu
INITIAL START UP
You can set the starting method when the mains plug
is connected to mains socket.
Change setting
Projector starts from the last image
LAST MEMORY
before the mains plug was
disconnected
Projector starts in the standby
STANDBY
mode
ON
Projector starts immediately
INSTALLATION
When installing the projector, select the projection
method according to the projector position.
( page 18)
Change setting
DESK
projecting from front
Mounting in the ceiling with a ceiling
mount bracket (sold separately) and
CEILING
projecting from front
REAR/DESK
from rear (Translucent screen is
required)
Mounting in the ceiling with a ceiling
mount bracket (sold separately) and
REAR/CEILING
projecting from rear (Translucent
screen is required)
If you use the projector at high elevation, the
ALTITUDE MODE setting need to be ON to set the
fan speed high.
Change setting
For use in normal environment
ON
For use at high altitude
At 1 400 -2 700 m (4 593 - 8 858 ft) sea level, the
setting must be ON.
The loudness of fan noise depends on the
ALTITUDE MODE setting.
Change setting
Change setting
Change setting
E