Parameter operation for Recall Safe/
Selective Recall (from V1.12)
When using Recall Safe or Selective Recall, there has been a
change in the behavior of parameters of which only one
exists for each pair of adjacent odd-numbered/even-num-
bered channels or modules (see owner's manual p.165). If
Recall Safe or Selective Recall is specified for only one of
these channels or modules, the parameters will behave as
follows.
• PAIR
Forcibly turned off (pairing will be defeated).
• GATE STEREO LINK
• COMP STEREO LINK
• GEQ LINK
LINK parameters will be forcibly turned off (link will be
defeated).
• DELAY GANG
• ATT GANG
GANG parameters will be recalled. If GANG turns On
because of the recall, the relative differences of the
DELAY and ATT parameter values following the recall
will be maintained when they are edited.
• MS DECODE
• FIXED/VARI
These will not be recalled.
• PAN MODE
The PAN MODE parameter will be recalled. However, if
the recall would cause the PAN MODE setting to change
from BALANCE to some other setting, or from some
other setting to BALANCE, then the PAN MODE and
PAN parameters will not be recalled. Also, if the recall
causes the PAN MODE to become GANG PAN, the rel-
ative difference of the PAN parameter values following
the recall will be maintained when they are edited.
Support for the Y96K card (from V1.10)
A PLUG-IN screen has been added to the EFFECT func-
tion. Also, PLUGIN parameters have been added to the
RECALL SAFE screen and SELECTIVE RECALL screen of
the SCENE function. These additions are in order to sup-
port the Y96K card that will become available in the near
future from the Waves Corporation. For details on opera-
tion, refer to the owner's manual for the Y96K.
Please note that the Y96K card will operate as follows.
• Data will be stored/recalled as scene data, but the Undo
function is not supported.
• If you power-off and then power-on the PM5D, con-
ventional scene data will be in the same state as when
you powered-off, but the Y96K will be in the state that
was last stored or recalled.
• If you recall a scene that produces a major change in the
settings of the Y96K, the settings of the Y96K will change
several seconds after recall occurs on the PM5D. If you
want the timing of the change to be synchronized, use
the FADE TIME screen to specify a START OFFSET.
• Do not perform scene store/recall operations in the
Y96K's update waiting screen. If you do so, the screen
will become inoperable for up to 30 seconds.
• The Scene Store operation saves the Y96K settings in the
PM5D. If you executed Scene Store while the Y96K had
previously been installed, and then once again store the
scene with the Y96K not installed, the previous Y96K
settings will remain. If a scene has never been stored
while the Y96K is installed, recalling that scene with the
Y96K installed will not affect the Y96K in any way.
• In PREVIEW mode, the PLUG-IN screen does not dis-
play the Y96K status.
MIDI EVENT etc. data now maintained
during scene recall (from V1.05)
The MIDI EVENT, GPI OUT CONTROL, and REMOTE
TRANSPORT data included in a scene is now maintained
when a scene recall occurs. This means that if you store a
recalled scene into another scene, this data will be stored as
it was when recalled.
DME series monitor source selection and
EXTERNAL CUE on/off (from V1.05)
A MONITOR button and monitor source select button have
been added to the DME CONTROL screen. When you click
the monitor source select button ( ), the MONITOR
POINT SELECT window will appear, letting you select the
DME series unit monitor source. If the MONITOR button
is on, the EXTERNAL CUE indicator in the upper part of
the display will turn on, and the monitor signal of the DME
series unit will be sent to the PM5D's CUE bus.
Note
Before turning on the MONITOR button, you must select the
same port as the monitor output on the DME series unit and
as the monitor input for the PM5D. To specify the DME series
unit monitor output, use the "Monitor Out" dialog box of DME
Designer, accessed by [Tools] menu → [Monitor]. To specify
the PM5D monitor input, use the MONITOR PORT field on the
SETUP page of the DME CONTROL screen.
DME64N/24N version (from V1.12)
In order to use the DME CONTROL functionality, the
PM5D must be V1.12 or higher, and all connected
DME64N/24N units must be version 1.1 or higher.