WARNING!
Read the instructions carefully before installing and/or using the hood.
Before connecting, make sure that the mains voltage corresponds to the voltage on
the rating plate inside the hood. (see fig. 7)
Once you remove the appliance from its packaging make sure it is intact. If the
product is damaged, do not use it and contact the Smeg assistance network.
It is recommended that a qualified technician performs installation and adjustment
.
operations
The minimum distance between the cooker and the lower part of the hood must be
750mm for gas cookers and 650 mm for electric cookers.
Before carrying out any kind of maintenance or cleaning, disconnect the hood from
the mains supply.
Inspect and clean the filters thoroughly and in accordance with the intervals
suggested by the manufacturer.
Do not cook or fry in a way that could result in flames being sucked into the hood and
causing a fire.
The hood surface can be cleaned with a damp cloth and a non-bleach liquid
detergent.
Make sure the room is properly ventilated when using the hood and other gas
appliances at the same time.
Comply with the regulations on air discharge when operating the hood.
The extracted air must not be routed into a duct used to discharge fumes of gas-
operated appliances.
This appliance must not be used by children without an adult supervision
and disabled people may require assistance.
THE MANUFACTURER CANNOT BE HELD RESPONSIBLE IF THE ABOVE
INSTRUCTIONS ARE NOT FOLLOWED.
OPERATION
This appliance has been designed to work as a DUCTING hood (evacuation of the
air) or RECYCLING hood (recycling of the filtered air).
DUCTED MODE: In order to use the hood in the ducted mode, connect the motor
intake, by means of a suitable ducting hose not less than 120mm diameter, directly to
the external fumes outlet.
Note: Remove any carbon filters.
RECIRCULATION MODE: If it is not possible to discharge fumes outside, the hood
can be used to filter and recycle the air. This way, air and fumes are filtered by the
anti-odour carbon filters and recirculated through the aerating grids on the sides of
chimney.
EN
01

Advertisement

loading

Summary of Contents for Smeg CA12SHRPX

  • Page 1 (see fig. 7) Once you remove the appliance from its packaging make sure it is intact. If the product is damaged, do not use it and contact the Smeg assistance network. It is recommended that a qualified technician performs installation and adjustment...
  • Page 2: Installation Instructions

    INSTALLATION INSTRUCTIONS: Fig.1 Fig.2 Type 1 Type 2 Fig.3 Hood levelling screw The hood is supplied with all the necessary accessories for installation. The minimum distance between the cooker and the lower part of the hood must be 750 mm for gas cookers and 650 mm for electric cookers (Fig.
  • Page 3 Fig.4 Fig.5 Fig.6 Recirculation mode: Leave the motor intake free. Install the active carbon filters as shown in page 6. Warning: if the hood is not supplied with an active carbon filter, it is necessary to buy it separately and assemble it before using the hood.
  • Page 4 OPERATING INSTRUCTIONS: ü CONTROL PANEL: In order to achieve the best performance, it is recommended to start the hood a few minutes before starting cooking and keep it on for at least 15 minutes after finishing cooking or after all fumes and odours have disappeared. To start the hood, identify your type of control panel and follow the instructions: Ø...
  • Page 5: Cleaning And Maintenance

    OPTIONAL FUNCTIONS: - AUTO POWER-OFF TIMER: Pushing one of the speed adjustment buttons (2-3-4) twice, you will activate the “Auto power-off timer” function that turns the motor and light off 10 mins. The activation of such function is signalled by the blinking LED after above the pressed button.
  • Page 6 METAL FILTERS CLEANING: CARBON FILTERS REPLACEMENT: (For recirculated version only) Fig.A Fig.B Fig.C Special attention should be reserved to the metal grease filters. An excess of grease in the filter, as well as affecting the performance of the hood, can also be a fire risk.
  • Page 7: Lights Replacement

    LIGHTS REPLACEMENT: Before performing maintenance operation, disconnect the hood from the mains supply. According to the model, the hood can be equipped with different kind of lighting such as incandescent, halogen and neon lamps. Incandescent lamps: E14 – 40W 230V lamps. To replace them, remove the transparent fixture from the control panel, unscrew the lamp and screw in the new one.
  • Page 8: Warranty & Service

    WARRANTY SERVICE The hood packaging includes, together with this operating and maintenance booklet, the Smeg Warranty Booklet. Please read the Smeg Warranty Booklet for complete information about the warranty (N.B. bulbs and filters are not covered by your warranty). Fig.7...

This manual is also suitable for:

Ca12srxCa12shrxCa12srpxCa60epxCa60epx8Ca60ex ... Show all