IMPORTANT INSTALLATION
SPECIFICATIONS
The installer should note that the appliance
that side walls should be no higher than the
hot plate itself. Furthermore, the rear wall, the
surfaces surrounding and adjacent to the
appliance must be able to withstand an
temperature of 90 °C.
The adhesive used to stick the plastic laminate
to the cabinet must be able to withstand a
temperature of not less than 150 °C otherwise
the laminate could come unstuck.
The appliance must be installed in compliance
with the provisions in force.
This appliance is not connected to a device
able to dispose of the combustion fumes. It
must therefore be connected in compliance
with the above mentioned installation
standards. Particular care should be paid to
the following provisions governing ventilation
and aeration.
5) ROOM VENTILATION
It is essential to ensure that the room in which the
appliance is installed is permanently ventilated in
order to allow the appliance itself to operate correctly.
the necessary amount of air is that required for regular
gas combustion and ventilation of the relative room,
the volume of which must not be less than 20 m
must naturally flow through permanent openings in
the walls of the room in question. These openings
must vent the fumes outdoors and their section must
2
be at least 100 cm
(see fig. 3). Construction of the
openings must ensure that the openings themselves
may never be blocked. Indirect ventilation by air
drawn from an adjacent room is also permitted, in
strict compliance with the provisions in force.
CAUTION: if the burners of the cooking top are
without safety thermocouple, the ventilation
outlet must have a minimum 200 cm² section.
6) LOCATION AND AERATION
Gas cooking appliances must always dispose of their
combustion fumes through hoods. These must be
connected to flues, chimneys or straight outside. If it
is not possible to install a hood, an electric fan can be
installed on a window or on a wall facing outside (see
fig. 4). This must be activated at the same time as
the appliance (see fig. 5), so long as the
specifications in the provisions in force are strictly
complied with.

7) GAS CONNECTION

Before connecting the appliance, check that
the values on the data label affixed to the
underside of the hot plate correspond to those
of the gas and electricity mains in the home.
A label on the appliance indicates the
regulating conditions: type of gas and working
pressure. Gas connection must comply with
the pertinent standards and provisions in
force.
When gas is supplied through ducts, the
appliance must be connected to the gas supply
system:
INSTALLATION
● with a rigid steel pipe. The joints of this pipe
must consist of threaded fittings conforming to
the standards.
●With copper pipe. The joints of this pipe must
consist of unions with mechanical seals.
● With seamless flexible stainless steel pipe. The
length of this pipe must be 2 meters at most and
the seals must comply with the standards.
When the gas is supplied by a bottle, the
appliance must be fuelled by a pressure regulator
conforming to the provisions in force and must be
connected:
● with a copper pipe. The joints of this pipe must
consist of unions with mechanical seals.
● With seamless flexible stainless steel pipe. The
length of this pipe must be 2 meters at most and
the seals must comply with the standards. It is
advisable to apply the special adapter to the flexible
pipe. This is easily available from the shops and
facilitates connection with the hose nipple of the
pressure governor on the bottle.
At the connection end, verify the gasproof using a
soap solution, never a flame.
WARNINGS:
3
. Air
remember that the gas inlet union on the
appliance is a 1/2" gas cylindric male type in
compliance with ISO 228-1 standards.
Installation of stainless steel pipe and rubber
hose pipe must ensure that it is never able to
touch mobile parts of the built-in cabinet (eg.
drawers). Furthermore, it must not pass
through compartments that could be used for
storage purposes.
When using a rubber hose pipe, it is essential
to comply with the following instructions:
- no part of the pipe must be able to touch
parts the temperature of which exceeds 90
°C.
- The pipe must not be pulled or twisted,
throttled or tughtly bent.
- It must not come into contact with sharp
edges or corners.
- It must be easy to inspect the entire pipe
length in order to check its state of wear.
- The pipe must be replaced within the date
stamped on the pipe itself.
INSTRUCTIONS FOR GAS CONNECTION
Once the gas connection elbow has been
fitted, and if you need to remove it or change
its position, it is important to place the gaskets
(A) in-between the elbow (B) and the LPG
nipple (C) before you tighten it, (see fig to the
side.