Main Board - Sony CDP-C701ES Service Manual

Compact disc player
Table of Contents

Advertisement

RF PLL Free-run Frequency Check
Procedure:
1.
Connect frequency counter to test point (PLCK) with lead
wire.
frequency counter
Main
board
TP(PLCK)
O—¢-—-0+
2.
Turn Power switch on.
3.
Confirm that reading on frequency counter is 4.3218MHz.
Adjustment Locations:
{BD Board]
—Conductor Side—
(PLCK)
oO
{MAIN Board}
—Component Side—
7
\
7
'

Advertisement