Removal And Reinstallation Of The Operation Panel Or The Front Covers - Mitsubishi Electric FR-A802-F Series Instruction Manual

Table of Contents

Advertisement

2.2
Removal and reinstallation of the operation panel
or the front covers
 Removal and reinstallation of the operation panel
• Loosen the two screws on the operation panel.
(These screws cannot be removed.)
To reinstall the operation panel, align its connector on the back with the PU connector of the inverter, and insert the operation
panel. After confirming that the operation panel is fit securely, tighten the screws. (Tightening torque: 0.40 to 0.45 N·m)
 Removal of the lower front cover
(a)
(a) Remove the mounting screws to remove the lower front cover. (The number of screws differs depending on the capacity
of the inverter.)
(b) With the lower front cover removed, the main circuit can be wired.
• Press the upper edge of the operation panel while pulling
out the operation panel.
(b)

2.2 Removal and reinstallation of the operation panel or the front covers