Service Modes; Boiler Reset - Philips Senseo Up HD7880/86 Service Manual

Table of Contents

Advertisement

SERVICE MODES

Manual pump calibration
1. Keep the regular- and strong cup button pressed while connecting the mains voltage to the appliance.
2. The buttons can be released when the regular- and strong cup LEDs are switched on.
a.
Press and release the strong cup button to decrease the calibration value. The strong and regular cup LEDs
blink for 0,5 second.
b. Press and release the regular cup button to increase the calibration value. The strong and regular cup LEDs
blink for 0,5 second.
c. Press and release the strong and regular cup buttons to store the calibration value. The strong and regular
cup LEDs blink for 1 second.
*) Service step 2a and 2b can repeatedly be used to adjust the calibration value. Use service step 2c to store the new
calibration value.
Mid-end / High-end selection
This steps follows automatically after step 2c, storing the newly calibrated value. To skip the calibration, simply press the regular and
stong button again after you connected the mains.
3. If the strong cup LED is on, the appliance is a ME version. If the regular cup LED is on, the appliance is a HE version.
a.
Press and release the strong cup LED to make the appliance a ME version.
b. Press and release the regular cup LED to make the appliance a HE version.
c. Press and release the strong and regular cup buttons to store the HE/ME selection value. The strong and
regular cup LEDs blink for 1 second.

Boiler reset

1. Keep the strong cup button pressed while connecting the mains voltage to the PCBA.
2. Button can be released when the strong cup LED or regular cup LED blinks rapidly. The strong cup LED will burst in
case of a ME version. The regular cup LED will burst in case of a HE version.
HD7880/86 / HD7880/87