Hz). The shockproof socket must be installed
in accordance with the regulations.
The following types of mains cable are suitable,
taking the necessary rated cross section into
account: H07 RN-F, H05 RN-F, H05 RR-F, H05
VV-F, H05 V2V2-F (T90), H05 BB-F.
The connection cable must in any case be laid
out so that at no point does it reach 50°C (over
room temperature).
After the connection has been carried out, the
heating elements must be tested by being
operated for about 3 minutes.
Terminal block
The oven is fitted with an easily accessible ter-
minal block which is designed to operate with
a single-phase power supply of 230 V.
Instructions for Building In
Please ensure that when the oven is instal-
led it is easily accessible for the engineer in
the event of a breakdown.
Building in
The surround or cabinet into which the oven will
be built must comply with these specifications:
Letter L - Live terminal
Letter N - Neutral terminal
or E - Earth terminal
For UK use only
Connection
Min. size
via
Cable/flex type
13 A socket
2.5 mm
outlet
13 A spur box
Oven
2.5 mm
Control
Circuit
• the dimensions must be as shown in the
relevant diagrams;
• the materials must withstand a temperature
increase of at least 60 °C above ambient;
• proper arrangements must be made of a
continuous supply of air to the oven to pre-
vent the oven overheating.
50
Cable / flex Fuse
2
3 core
13 A min.
butyl
insulated
2
PVC/PVC
15 A min.
twin and
20 A max.
earth