Page 1
Servicing ............. 2 Parts ............3 Exploded views ..........4 Schematics ........... 5 Published by Technical Publications Zenith Electronics Corporation 201 James Record Road - Huntsville, Alabama 35824-1513 Printed in U.S.A. Copyright October 2001 by Zenith Electronics Corporation CN DG 5k...
Page 2
When servicing this product, under no circumstances should the original design be modified or altered without permission from Zenith Electronics Corporation. All components should be replaced only with types identical to those in the original circuit and their physical location, wiring and lead dress must conform to original layout upon completion of repairs.
SPECIFICATIONS MODEL REMARKS H13A02D / H13A02X ITEMS TV STANDARD NTSC-M POWER INPUT AC 120V 60 Hz POWER CONSUMPTION TUNING SYSTEM Frequency Synthesizer ( FS ) Tuning System VHF : 2 ~ 13 (12) UHF : 14 ~ 69 (56) TUNING RANGES...
SERVICE MODE LIST This unit provided with the following SERVICE MODES so you can repair, examine and adjust easily. To enter the Service Mode, press both set key and remote control key for more than 1 second. Set Key Remocon Key Operations Releasing of V-CHIP PASSWORD.
R E M Z enith NOTE If you changed the setting of “REM Zenith” item , then your rem ote control w ill not work. In that case, unplug your power cord and plug it again. • Using the channel up or channel down button, select the item you wish to adjust.
Page 9
DISASSEMBLY INSTRUCTIONS 3. After one side is removed, pull in the opposite direction to 1. REMOVAL OF ANODE CAP remove the other. Read the following NOTED items before starting work. NOTE After turning the power off there might still be a potential Take care not to damage the Rubber Cap.
ELECTRICAL ADJUSTMENTS 1. BEFORE MAKING ELECTRICAL 2. BASIC ADJUSTMENTS ADJUSTMENTS 2-1: RF AGC DELAY Read and perform these adjustments when repairing the Place the set with Aging Test for more than 15 minutes. circuits or replacing electrical parts or PCB assemblies. Receive a 64dB monoscope pattern.
Page 11
ELECTRICAL ADJUSTMENTS 2-8: HORIZONTAL PHASE 2-5: SUB CONTRAST Receive a Crosshatch pattern. Activate the adjustment mode display of Fig. 1-1 and Activate the adjustment mode display of Fig. 1-1 and press the channel button (14) on the remote control to press the channel button (05) on the remote control to select "CONTRAST".
Page 12
ELECTRICAL ADJUSTMENTS PURITY AND CONVERGENCE 3-3: STATIC CONVERGENCE ADJUSTMENTS NOTE Adjust after performing adjustments in section 3-2. NOTE Receive the crosshatch pattern from the color bar Turn the unit on and let it warm up for at least 30 generator. minutes before performing the following adjustments.
H13A02D/02X Main Micro & Tuner Circuit TU001NJH3022U268 This schematic ref ers to the following models Red Drive TP001 H13A02D JWF-50K-1 Green Drive H13A02X Blue Drive C003 FROM/TOCHROMA OS101 50VKA PIC-28141SY-2 1 0.5V 50 ns/div 2.2uF L001 TUNER+5V 10uH0607 R002 R001...
H13A02D/02X PCB Layout Bottom R604 C113 R603 C138 C127 R620 IC101 R122 R420 R632 R639 C643 C411 R602 R359 R353 R357 R513 R512 R813 R131 NOTE: THE DC VOLTAGE AT EACH PART WAS MEASURED WITH A COLOR CRITICAL SAFETY COMPONENTS ARE IDENTIFIED BY THE SYMBOL...