Leakage Test - Sony ICF-9740W Service Manual

Fm/am 2-band radio
Hide thumbs Also See for ICF-9740W:
Table of Contents

Advertisement

~~
Ve
9-950-543-81
US Model
No. 1
March, 1983
SUPPLEMENT
File this supplement with the service manual.
SAFETY
CHECK-OUT
(US Model)
After
correcting
the
original
service
problem,
perform the following safety check before releasing
the set to the customer:
Check the antenna terminals, metal trim, "'metallized"'
knobs, screws, and all other exposed metal parts for
AC leakage.
Check leakage as described below.
LEAKAGE
TEST
The AC leakage from any exposed metal part to
earth ground and from all exposed metal parts to any
exposed
metal
part having a return
to chassis, must
not
exceed
0.5 mA
(500
microampers).
Leakage
current
can
be
measured
by
any one
of
three
methods.
1.
A
commercial
leakage
tester,
such
as
the
Simpson 229 or RCA WT-540A.
Follow the
manufacturers' instructions to use these instru-
ments.
tO
A battery-operated
AC milliammeter.
The Data
Precision
245
digital multimeter is suitable for
this job.
3.
Measuring the voltage drop across a resistor by
means
of a VOM
or battery-operated
AC volt-
meter.
The
"limit"? indication
is 0.75 V, so
analog
meters
must
have
an
accurate
low-
voltage
scale.
The
Simpson
250 and
Sanwa
SH-63Trd
are examples of a passive VOM
that
is suitable.
Nearly all battery operated
digital
multimeters
that
have
a 2V
AC
range
are
suitable.
(See Fig. A)
To Exposed Metal
Parts on Set
AC
vo/tmeter
(0. 75 VY)
"=
£arth Ground
Fig. A.
Using an AC voltmeter to check AC leakage.