Alarm
Description
Communication incongruence
E92
between main PCB and display
(incompatible versions)
E93
Appliance configuration error
Incorrect configuration of washing
E94
cycle
Incongruence between programme
E97
selector and cycle configuration
E9C
Display board configuration error
EC4
AGS current sensor faulty.
Drain filter clogged
EF1
(drain phase too long)
Overdosing of detergent
EF2
(too much foam during drain
phases)
EF3
Aqua control system intervention
EF5
Unbalanced load
EF6
Reset
Supply frequency of appliance
EH1
outside the limits
EH2
Supply voltage too high
EH3
Supply voltage too low
2010 SOI/DT-mdm FCPD-dp Quality-tb
Guide to diagnostics for electronic controls EWM0931x
Possible fault
Incorrect control/display PCB;
Incorrect PCB (do not correspond to the model).
Main PCB faulty (Incorrect configuration data);
Main PCB faulty (Incorrect configuration data);
Main PCB faulty (Incorrect configuration data).
Display board
Main board faulty.
Drain filter clogged/dirty.
Drain hose blocked/kinked/too high;
Excessive detergent dosing; Drain hose kinked/blocked;
Drain filter clogged/dirty.
Water leaks onto base frame; Aqua control system faulty.
Final spin phases skipped
If it continues, replace the main board.
Problems with the power supply network (incorrect/disturbed); Main
PCB faulty.
Problems with the power supply network (incorrect/disturbed); Main
PCB faulty.
Problems with the power supply network (incorrect/disturbed); Main
PCB faulty.
Spin speed reduced to safety speed of
Warning displayed at the end of cycle START/RESET
Warning displayed after 5 attempts or
17/67
Machine status/action
Reset
Cycle blocked
ON/OFF
Cycle blocked
ON/OFF
Cycle blocked
ON/OFF
Cycle blocked
RESET
START
----------------
ON/OFF
RESET
RESET
150 rpm
RESET
by the specific LED
Appliance drains
ON/OFF RESET
----------------
START/RESET
No action to be taken
----------------
Wait for nominal
ON/OFF
frequency conditions
Wait for nominal
ON/OFF
voltage conditions
Wait for nominal
ON/OFF
voltage conditions