Electrical Specification - Hitachi CML156XW Service Manual

Hide thumbs Also See for CML156XW:
Table of Contents

Advertisement

6.4 Electrical Specification:

6.4.1 AC-DC Electrical Specification
6.4.1
Input Specification
No
Item
1
Input Voltage
2
Input Frequency
3
Input Current
4
Inrush Current
5
Hold Up Time
6
Turn on time
7
Efficiency
Input Power
8
Consumption
*Cold start-up of Inrush Current : Power board off (keep over 1 hour) and Tamb=25degree C
6.4.1 AC-DC Output Specification
Output
Output Voltage
+5Vdc
+12Vdc
Ripple
Noise
Dynamic Load
Regulation
Over / Under
Shoot
*+5Vcc load regulation test: +12V loading at 1.0A
*+12Vcc load regulation test: +5V loading at 1.0A
Protection Function: Auto-recovery design is acceptable but input power must
be less than 5W
Condition
-----
-----
100Vac @ Type load 1.5A
Cold Start @ Vin=100Vrms
Cold Start @ Vin=220Vrms
@ full load & 100Vac input and Type
load
Vin =110Vac
+12V/1.5A ,+5Vcc/1.5A
Vin=220Vac
Tolerance
-
+5 /-3 %
+25/-5 %
1. Measured at DC output
terminals which are
paralleled with a 10uF
E-Cap & 0.1uF Ceramic
Cap.
2.Band width is limited
within 20MHz.
50~100% or 100~50%
load change of any DC
output @50% duty of
1MHz (min.)
@ Power line on/off
Min.
100
47
---
---
10
---
70
---
Output Current
MIN
MAX
0.05A
1.5A
0A
1.5A
---
---
±5%
---
±5%
---
21
Typ.
Max.
---
240
---
63
---
1.0
---
30
---
50
---
---
1.0
---
---
---
---
1.2
Voltage Tolerance
4.85~5.25V dc
11.4~15Vdc
+5Vdc:50mVp-p
1%
+12Vdc:120mVp-p
+5Vdc:150mVp-p
3%
+12Vdc:360mVp-p
---
Unit
Vac
Hz
Arms
A
0-P
A
0-P
ms
S
%
W

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cml158xw

Table of Contents