Table Of Contents; Precautions - Bosch Climate 5000 VRF FSC-B Series Installation & User Manual

Digital scroll and dc/ac inverter commercial air-conditioner
Hide thumbs Also See for Climate 5000 VRF FSC-B Series:
Table of Contents

Advertisement

2 | PRECAUTIONS

CONTENTS
1. PRECAUTIONS .................................................................... 2
2. INSTALLATION INFORMATION .............................................. 3
3. SUPPLIED FITTINGS ............................................................ 4
4. INDOOR UNIT INSTALLATION ............................................... 4
5. INSTALL THE CONNECTING PIPE .......................................... 7
6. CONNECT THE DRAIN PIPE .................................................. 7
7. WIRING .............................................................................. 8
8. TROUBLE SHOOTING ......................................................... 11
9. TEST OPERATION .............................................................. 12
1. PRECAUTIONS
Ensure you install according to national regulations.
Read "PRECAUTIONS" carefully before installation.
The following precautions include important safety items.
Keep this manual with the owner's manual for future reference.
The safety precautions listed here are divided into two categories. In either
case, important safety information is listed which must be read carefully.
WARNING
Failure to observe a warning may result in serious injury.
CAUTION
Failure to observe a  caution may result in injury or damage to
the equipment.
After completing the installation, make sure that the unit operates properly
during the  start-up operation. Please instruct the  customer on how to
operate the  unit and keep it maintained. Also, inform customers that they
should store this installation manual along with the owner's manual for future
reference.
WARNING
Only trained and qualified service personnel to install, repair or
service the equipment.
Incorrect installation, repair, and maintenance may result in electric
shocks, short-circuit, leaks, fire or other damage to the equipment.
Install according to this installation instructions strictly.
If installation is defective, it will cause water leakage, electrical shock
and fire.
Disconnect the power supply before cleaning and maintenance.
When installing the unit in a small room, take measures against to
keep refrigerant concentration from exceeding allowable safety
limits in the event of refrigerant leakage.
Contact your installer.
Excessive refrigerant in a closed ambient can lead to oxygen deficiency.
6720866023 (2017/11)
PAGE
Use the  attached accessories parts and specified parts for
installation.
Otherwise, it will cause the unit to fail, water leakage, electrical shock
fire.
Install the unit on a load bearing surface which is able to withstand
the units weight.
If the strength is not enough or installation is not properly done, the unit
will fall and could to cause injury.
The appliance shall not be installed in the laundry room.
Before obtaining access to terminals, all power supplies must be
disconnected.
For electrical work, follow the  local national wiring standard,
regulation and this installation instructions. An independent
circuit and single outlet must be used.
If electrical circuit capacity is not enough or defect in electrical work, it
will cause electrical shock and fire.
Use the specified cable and connect tightly and clamp the cable so
that no external force will be acted on the terminal.
If connection or fixing is incorrect, it will cause heat-up or fire at
the connection.
Wiring routing must be properly arranged so that the control board
cover is fixed properly.
If control board cover is not fixed perfectly, it will cause heat-up at
connection point of terminal, fire or electrical shock.
If the power cable is damaged, it must be replaced by the manufac-
ture or its service agent or a similarly qualified person in order to
avoid a hazard.
An all-pole disconnection switch having a contact separation of at
least 3mm in all poles should be connected in fixed wiring.
When carrying out refrigeration piping connection, take care not
to let air substances get into the refrigeration cycle.
Otherwise, it will cause lower capacity, abnormal high pressure in
the refrigeration cycle, explosion and injury.
Do not modify the  length of the  power cable or use of extension
cable, and do not share the single outlet with any other electrical
appliances.
Otherwise, it will cause fire or electrical shock.
Carry out the specified installation work after taking into account
strong winds.
Improper installation work may result in the  equipment falling and
causing accidents.
If the  refrigerant leaks during installation, ventilate the  area
immediately.
Toxic gas may be produced if the  refrigerant comes into the  place
contacting with fire.