Hydro Unit(Mono); Eeprom Error - Samsung AEX160EDEHA Service Manual

Table of Contents

Advertisement

4-3 Hydro Unit

4-3-1 EEPROM error

Outdoor unit display
Indoor unit display
Criteria
Cause of problem
1. How to check
42
RC160MHXGA_SM_E_34513A(1)_4.indd 42
◑(Timer)
◑(Fan)
×(Operation)
Communication failure between EEPROM and MICOM
Check the location of EEPROM by
referring to the schematic diagram
Are there any problems
such as short or dewetting between
EEPROM PIN?
Yes
If you restart after reentering
model options and power reset, does the
error occur again?
Yes
Replace PCB
◑(Filter)
×(Defrost)
No
Replace PCB
No
Normal operation