Advertisement

Quick Links

OPERATION MANUAL
AIR CONDITIONER (Wall-Mounted type)
□ ASTH24CNTA
MODEL:
* Check the model name.
(Refer to the rating label.)
Before using this product, read these
instructions thoroughly and keep this
manual for future reference.
Contents
1. SAFETY PRECAUTIONS .......................................... 1
2. PREPARATION ......................................................... 2
2.1. Inserting batteries ............................................. 3
3. NAME OF PARTS ..................................................... 3
3.1. Indoor unit ........................................................ 3
3.2. Remote controller ............................................. 3
4. BASIC OPERATIONS ............................................... 5
5. AIRFLOW SETTINGS ............................................... 5
5.1. Fan speed setting ............................................. 5
5.2. Airflow direction setting .................................... 5
6. TIMER OPERATIONS ............................................... 5
6.1. On timer or Off timer ......................................... 6
6.2. Program timer ................................................... 6
6.3. Sleep timer ...................................................... 6
7. ENERGY SAVING OPERATIONS ............................ 6
7.1. Economy operation .......................................... 6
7.2. Fan control for energy saving ........................... 6
7.3. Demand Response ........................................... 6
8. OTHER OPERATION ................................................ 7
8.1. Powerful operation ........................................... 7
9. SETTINGS ON INSTALLATION ................................ 7
10. CLEANING AND CARE ............................................. 7
11. GENERAL INFORMATION ....................................... 9
12. OPTIONAL PARTS ................................................... 9
12.1. Wired remote controller .................................... 9
13. TROUBLESHOOTING .............................................. 9
PART No. 9387602463-01
R32
REFRIGERANT
This Air Conditioner contains and
operates with refrigerant R32.
THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED
BY QUALIFIED PERSONNEL.
Refer to Commonwealth, State, Territory and local legislation,
regulations, codes, installation & operation manuals, before
the installation, maintenance or service of this product.
En-1

1. SAFETY PRECAUTIONS

To prevent personal injury or property damage, read this section
carefully before you use this product, and be sure to comply
with the following safety precautions.
Incorrect operation due to failure to follow the instructions may
cause harm or damage, the seriousness of which is classified
as follows:
WARNING
This mark warns of death or serious injury.
CAUTION
This mark warns of injury or damage to property.
This mark denotes an action that is PROHIBITED.
This mark denotes an action that is COMPULSORY.
Explanation of symbols displayed on the indoor unit or outdoor unit.
WARNING
This symbol shows that this product uses a low
burning velocity material. If the refrigerant is leaked
and exposed to an external ignition source, there is a
risk of fire.
CAUTION
This symbol shows that the operation manual should
be read carefully.
CAUTION
This symbol shows that a service personnel should
be handling this equipment with reference to the
installation manual.
CAUTION
This symbol shows that information is available such
as the operation manual or installation manual.
WARNING
• When installing this product to an unventilated area,
pay attention to prevent fire and explosion caused
by the stagnated gas in case of refrigerant leakage.
(For products which contain more than 1.842 kg
refrigerant.)
• This product contains no user-serviceable parts.
Always consult authorized service personnel for
repairing, installation, and relocation of this product.
Improper installation or handling will cause leakage,
electric shock, or fire.
• In the event of a malfunction such as burning smell,
immediately stop operation of the air conditioner, and
disconnect all the power supply by turning off the
electrical breaker or disconnecting the power plug.
Then consult authorized service personnel.
• Take care not to damage the power supply cable.
If it is damaged, it should be replaced only by
authorized service personnel in order to avoid a
hazard.

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu AIRSTAGE ASTH24CNTA

  • Page 1: Table Of Contents

    OPERATION MANUAL 1. SAFETY PRECAUTIONS AIR CONDITIONER (Wall-Mounted type) To prevent personal injury or property damage, read this section carefully before you use this product, and be sure to comply with the following safety precautions. Incorrect operation due to failure to follow the instructions may cause harm or damage, the seriousness of which is classified as follows: WARNING...
  • Page 2: Preparation

    WARNING CAUTION • If a refrigerant leakage is suspected, all naked • The airflow direction and the room temperature should flames shall be removed or extinguished, and consult be carefully considered when you use this product in a authorized service personnel. room with infants, children, elderly or sick persons.
  • Page 3: Inserting Batteries

    Indoor unit accessories 3.1. Indoor unit Check that the following accessories are included. For Manual auto operation and Filter indicator reset (Refer to page 10.) Intake grille Rating label Air cleaning filters Front panel (Apple catechin filter,Ion deodorization filter) Remote controller Remote controller Self-tapping screws holder...
  • Page 4 Signal transmitter : The setting must be done while the setting screen is displayed Aim at the signal receiver of the indoor unit properly. for each function. • Operating range is approximately 7 m. : The button is controllable only when the air conditioner is •...
  • Page 5: Basic Operations

    ■ Airflow direction range 4. BASIC OPERATIONS Up/down airflow direction Change by ■ 3 steps to start operation 1 ⇄ 2 ⇄ 3 ( ⇄ 4 ⇄ 5 ⇄ 6) Cooling, Dry 1. Press to start or stop the operation. 1 ⇄...
  • Page 6: On Timer Or Off Timer

    6.1. On timer or Off timer 7. ENERGY SAVING OPERATIONS 1. Select On timer or Off timer in step 1 of “Timer setting 7.1. Economy operation procedure.” 2. Each time you press , the time changes It saves more electricity than other operation modes by changing the set as follows: temperature to a moderate setting.
  • Page 7: Other Operation

    (2) Is the air conditioner under the Demand controlling? conditioner. Contact your electricity supplier. 10. CLEANING AND CARE No • Contact Fujitsu General (AUST.) PTY LIMITED. (Refer to your warranty card.) CAUTION • Visit our website (www.fujitsugeneral.com.au). • Before cleaning this product, be sure to turn it off and disconnect all the power supply.
  • Page 8 5. Rinse the Ion deodorization filter with water flow. Cleaning indoor unit body 6. Dry the Ion deodorization filter in the shade. NOTES: 7. Set the new or washed air cleaning filters into the air • Do not use water hotter than 40°C. cleaning filter holders.
  • Page 9: General Information

    Additional inspection 12. OPTIONAL PARTS After long period of use, accumulated dust inside the indoor unit may reduce the performance even if you have maintained the unit properly. 12.1. Wired remote controller In such a case, a product inspection is recommended. For more information, consult authorized service personnel.
  • Page 10 Timer setting error because of Auto restart Humidity does not drop during the Dry operation. ⇒ Reset the clock and timer settings. □ You cannot set the target humidity in the Dry mode. If you feel high humidity, set the temperature lower. Test run operation (for authorized Airflow is weak or stops.

Table of Contents