6. DISASSEMBLY
6.1 BASE AND PANEL
1.
2.
3.
First remove
the
top cover
by undoing
the
4 securing screws @.
Then disconnect the connector
@ plugged into
the printed circuit board.
And disconnect the connector
@ plugged into
the motor.
6.2 MOTOR
1.
2.
First
remove
the
panel
as described
above
under section 6.1.
Then undo the 3 screws
@ securing the motor.
6.3 SUB-PANEL ASSEMBLY AND TONEARM
1.
2.
3.
BASE (Fig. 15)
First
remove
the
panel
as described
above
under section 6.1.
Then undo the 3 screws @ securing the tone-
arm base and the sub-panel assembly.
Use a soldering
iron to disconnect the tone-
arm lead wires.
. Undo the 2 screws @ (located underneath the
sub-panel assembly) securing the tonearm base
to the sub-panel assembly.
. Next undo the screws
@ securing the 4 insu-
. Lie the tonearm
over towards the center, and
lators.
carefully lift the panel up and off.
Top cover
Fig. 13
g7-Sub-panel
assembly
Fig. 15
6.4 TONEARM
(Fig. 16)
13
1.
2.
3.
2.
3.
First separate the tonearm base from the sub-
panel
assembly
as
described
above
under
section 6.3.
Use a hexagonal wrench to loosen the 2 screws
@. Then remove the PU plate assembly.
Use
the
same
hexagonal
wrench
to loosen
screw @, and lift the tonearm
out from the
tonearm base.
6.5 PUSH-BUTTON UNIT (Fig. 17)
1.
First
remove
the
panel
as described
above
under section 6.1.
Pull the RECORD SIZE SELECTOR
@ up and
out.
Undo the 3 screws @ securing the control base
unit.
. Then
undo the 2 screws
@ securing the push-
button unit.
PL-3000
PU plate assembly
Fig. 16
Push-button
unit
Fig. 17