2.3.5

Connection to the PU connector

Using the PU connector, you can perform communication operation from the parameter unit (FR-PA07), enclosure surface
operation panel (FR-PA07), or a personal computer, etc.
Parameter setting and monitoring can be performed by FR Configurator (FR-SW3-SETUP-W).
Remove the inverter front cover when connecting.
When connecting the parameter unit or enclosure surface operation panel using a connection cable
Use the optional FR-CB2 or connector and cable available on the market.
Insert the cable plugs securely into the PU connector of the inverter and the connection connector of the FR-PU07, FR-PA07
along the guide until the tabs snap into place.
Install the inverter front cover after connecting.
FR-PA07 (option)
REMARKS
 Refer to the following when fabricating the cable on the user side. Keep the total cable length within 20m.
Examples of product available on the market (as of February 2015)
Product
Communication cable
RJ-45 connector
Parameter unit connection cable
(FR-CB2
) (option)
PU connector
FR-PU07 (option)
Type
SGLPEV-T (Cat5e/300m)

24AWG
4P
5-554720-3
Control circuit specifications
Manufacturer
Mitsubishi Cable Industries, Ltd.
Tyco Electronics
2
29