Cisco Nexus 9232E-B1 Hardware Installation Manual

Nx-os mode switch

Advertisement

Quick Links

Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation
Guide
First Published: 2023-12-14
Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 527-0883

Advertisement

Table of Contents
loading

Summary of Contents for Cisco Nexus 9232E-B1

  • Page 1 Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide First Published: 2023-12-14 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883...
  • Page 2 Any products and features described herein as in development or available at a future date remain in varying stages of development and will be offered on a when-and if-available basis. Any such product or feature roadmaps are subject to change at the sole discretion of Cisco and Cisco will have no liability for delay in the delivery or failure to deliver any products or feature roadmap items that may be set forth in this document.
  • Page 3: Table Of Contents

    Unpacking and Inspecting the Switch Installing the Switch Using the NXK-ACC-KIT-1RU Rack-Mount Kit Grounding the Chassis Starting the Switch C H A P T E R 4 Connecting the Switch to the Network Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 4 Switch Power Input Requirements Power Specifications 2000-W AC Power Supply Specifications Power Cable Specifications Power Cables for NXA-PAC-2KW Power Supplies Regulatory Standards Compliance Specifications A P P E N D I X C LEDs Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 5 Contents Switch Chassis LEDs Fan Module LEDs Power Supply LEDs A P P E N D I X D Additional Kits Rack Mount Kit NXK-ACC-KIT-1RU Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 6 Contents Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 7: Overview

    Overview • Overview, on page 1 Overview The Cisco Nexus 9232E-B1 switch (N9K-C9232E-B1) is a 1-rack unit (RU), fixed-port switch designed for deployment in data centers. This switch includes the following ports: • QSFP-DD800 ports (32) • Control Plane Expansion port (10G) •...
  • Page 8 To determine which transceivers, adapters, and cables are support this switch, see the Cisco Transceiver Modules Compatibility Information document. The following figure shows the switch features on the power supply side of the chassis. Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 9 If the switch has port-side exhaust airflow (blue coloring for fan modules), you must locate the ports in the hot aisle. If you locate the air intake in a hot aisle, the switch can overheat and shut down. Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 10 Overview Overview Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 11: Preparing The Site

    Altitude Requirements Altitude rating is 10,000 ft (3048 m). For China, it is 6,562 ft (2000 m). Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 12: Dust And Particulate Requirements

    The wiring is unlikely to emit radio interference if you use a twisted-pair cable with a good distribution of grounding conductors. If you exceed the recommended distances, use a high-quality twisted-pair cable with one ground conductor for each data signal when applicable. Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 13: Shock And Vibration Requirements

    The surfaces shall be cleaned and an antioxidant applied before installation. Planning for Power Requirements The switch includes two power supplies (1-to-1 redundancy with current sharing) in one of the following combinations: • Two 2000-W AC power supplies Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 14: Airflow Requirements

    Rack and Cabinet Requirements You can install the following types of racks or cabinets for your switch: • Standard perforated cabinets • Solid-walled cabinets with a roof fan tray (bottom-to-top cooling) Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 15: Clearance Requirements

    Provide the chassis with adequate clearance to route cables, provide airflow, and maintain the switch. For the clearances required for an installation of this chassis in a four-post rack, see the following figure. Chassis Depth of the chassis Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 16 19.0 in (43.3 cm) Note Both the front and rear of the chassis must be open to both aisles for airflow. Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 17: Installing The Chassis

    Starting the Switch, on page 20 Safety Before you install, operate, or service the switch, see the Regulatory, Compliance, and Safety Information for the Cisco Nexus 3000 and 9000 Series for important Safety Information. Warning Statement 1071 Warning Definition IMPORTANT SAFETY INSTRUCTIONS Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents.
  • Page 18 Only an instructed person or skilled person should be allowed to install, replace, or service this equipment. See statement 1089 for the definition of an instructed or skilled person. There are no serviceable parts inside. To avoid risk of electric shock, do not open. Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 19 To prevent personal injury or damage to the chassis, never attempt to lift or tilt the chassis using the handles on modules, such as power supplies, fans, or cards. These types of handles are not designed to support the weight of the unit. Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 20: Installation Options With Rack-Mount Kits

    You can install the switch using the following rack-mount options: • Rack-mount kit (NXK-ACC-KIT-1RU) which you can order from Cisco. This option offers you easy installation, greater stability, increased weight capacity, added accessibility, and improved removability with front and rear removal.
  • Page 21: Airflow Considerations

    Check for damage and report any discrepancies or damage to your customer service representative. Have the following information ready: • Invoice number of shipper (see packing slip) • Model and serial number of the damaged unit • Description of damage • Effect of damage on the installation Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 22: Installing The Switch Using The Nxk-Acc-Kit-1Ru Rack-Mount Kit

    The holes that you use depend on the requirements of your rack and the amount of clearance required for interface cables (3 inches [7.6 mm] minimum) and module handles (1 inch [2.5 mm] minimum). Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 23 (see the following figure). Tighten 12-24 screws to 30 in-lb (3.39 N·m) of torque and tighten 10-32 screws to 20 in-lb (2.26 N·m) of torque. Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 24 Holding the chassis level, insert screws (12-24 or 10-32, depending on the rack type) in each of the two front rack-mount brackets (using a total of six screws) and into the cage nuts or threaded holes in the vertical rack-mounting rails (see the following figure). Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 25: Grounding The Chassis

    This equipment must be grounded. To reduce the risk of electric shock, never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available. Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 26: Starting The Switch

    If you need n+n redundancy, you must connect each power supply in a switch to a different power source. Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 27 A setup utility automatically launches the first time that you access the switch and guides you through the basic configuration. For instructions on how to configure the switch and check module connectivity, see the appropriate Cisco Nexus 9000 Series configuration guide.
  • Page 28 Installing the Chassis Starting the Switch Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 29: Connecting The Switch To The Network

    When running cables in overhead or subfloor cable trays, we strongly recommend that you locate power cables and other potential noise sources as far away as practical from network cabling that terminates on Cisco equipment. In situations where long parallel cable runs cannot be separated by at least 3.3 feet (1 meter), we recommend that you shield any potential noise sources by housing them in a grounded metallic conduit.
  • Page 30 Connect the other end of the RJ-45 rollover cable to the console or to a modem. What to do next You are ready to create the initial switch configuration (see Creating the Initial Switch Configuration, on page 25). Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 31 To connect the switch to the network, you can use the default choices for each configuration except the IP address, which you must provide. You can perform the other configurations later as described in the Cisco Nexus 9000 Series NX-OS Fundamentals Configuration Guide.
  • Page 32 RJ-45 connectors. For longer connections, you can use an optical cable with SFP transceivers (LH or SX type). Note Use only one of these management ports—the switch does not support the use of both management ports. Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 33 When removing transceivers from the switch, it is best to remove the optical cable first and then remove the transceiver. To determine which transceivers, adapters, and cables are supported by this switch, see the Cisco Transceiver Modules Compatibility Information document. Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 34 Connecting the Switch to the Network Connecting Interface Ports to Other Devices Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 35 On the fan module that you are removing, press the two sides of the fan module handle together, and pull on the handles enough to unseat it from its connectors. Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 36 Pull the power cord out from the power receptacle on the power supply to be removed and verify that the LED turns off. The LED might be on and amber colored to indicate that the input power has been disconnected. Note Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 37 Attach the power cable to the electrical outlet on the front of the power supply. Step 4 Make sure that the other end of the power cable is attached to the appropriate power source for the power supply. Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 38 Depending on the outlet receptacle on your power distribution unit, you might need the optional jumper Note cable to connect the switch to your outlet receptacle. Step 5 Verify that the power supply is operational by making sure that the power supply LED is green. Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 39 • Standard 19-inch (48.3 cm) (two- or four-post EIA cabinet or rack, with mounting rails that conform to English universal hole spacing per section 1 of ANSI/EIA-310-D-1992). For more information, see Requirements Specific to Perforated Cabinets, on page Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 40 To help with cable management, you might want to allow additional space in the rack above and below the chassis to make it easier to route all of the fiber optic or copper cables through the rack. Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 41: Environmental Specifications

    Altitude rating is based on power supply installed; see critical components list in the system CB report for altitude rating. Switch Dimensions Switch Width Depth Height Cisco Nexus 9232E-B1 17.3 inches (43.9 cm) 23.6 inches (60.0 cm) 1.72 inches (4.4 cm) (1 RU) Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 42: Switch

    Requirement Cisco Nexus 9232E-B1 Power Specifications Power specifications include the specifications for each type of power supply module. 2000-W AC Power Supply Specifications These specifications apply to the NXA-PAC-2KW power supplies. Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 43: Power Cable Specifications

    The following sections specify the power cables that you can order and use with this switch. Power Cables for NXA-PAC-2KW Power Supplies Cable Description Illustration CAB-TA-NA North America AC Type A Power Cable CAB-TA-UK United Kingdom AC Type A Power Cable Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 44: Regulatory Standards Compliance Specifications

    12A CAB-TA-IN India AC Type A Power Cable CAB-TA-IS Israel AC Type A Power Cable Regulatory Standards Compliance Specifications The following table lists the regulatory standards compliance for the switch. Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 45 • CNS13438 Class A EMC: Immunity • EN55024 • CISPR24 • EN300386 • KN 61000-4 series RoHS The product is RoH-6 compliant with exceptions for leaded-ball grid-array (BGA) balls and lead press-fit connectors. Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 46 System Specifications System Specifications Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 47: Appendix

    The GPS interface is provisioned and frequency, time of day and phase inputs are all operating correctly. The GPS interface is not provisioned, or the GPS inputs are not working correctly. Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 48 The power supply LEDs are located on the left right portion of the power supply. Combinations of states indicated by the Okay and Fault LEDs indicate the status for the module as shown in the following table. Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 49 • Over temperature • Fan failure Flashing amber Power supply is operating but a warning condition has occurred---possibly one of the following conditions: • High temperature • High power • Slow fan Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 50 LEDs LEDs Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 51 Hazardous substances list for customers in China The following table lists and illustrates the console cable (CAB-CONSOLE-RJ45) that can be ordered. Illustration Description Quantity Console cable with DB-9F and RJ-45F connectors Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...
  • Page 52 Additional Kits Additional Kits Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide...

Table of Contents