iiis/muia ou
9 mm or less
9 mm ou moins
9 mm o menos
4 mm or less
4 mm ou moins
4 mm o menos
The lens must be either a C- or a CS-mount type of less than 1 kg. Tt
protrusion behind the mounting surface must be within the limits as
shown in illustration B
Changing the plug on an auto iris lens cable
The camera is supplied with a LENS connector for inserting the power
control cable of an auto iris lens. Before connecting an auto Iris lens
however, you first have to replace the lens cable plug with the one
supplied with this camera. Replace as follows:
1
Detach the old plug from the lens cable.
2
Solder the wires to the pins of the new plug. (For
cable
pin assign-
mentr refer to the instruction manual for the lens.)
o
Cover
©
Lens cable (not supplied)
©
Rib (If the cable is thick, cut this off.)
©
Plug (unit accessory)
0
Pin 4
Video signal control
Ground
DC control
DRV-
o
Pin 2
Video signal control
Not used
DC control
CONT +
©
Pin 1
Video signal control
Power supply (DC 9 V/Max. 50 mA)
DC control
CONT-
©
Pin 3
Video signal control
Video signal (0.7 Vp-p)
DC control
DRV +
Fitting the lens
Q
1
Unscrew the lens mount cap.
2
Screw in the lens, and turn it until it is secured.
3
Insert the lens plug in the LENS connector.
When fitting a manual-iris lens, omit step 3.
4
According to the type of lens, adjust the focal length by turning the
focal length adjustment ring.
5 Tighten the locking screw.
Keep the lens mount cap on the camera when not attaching a lens.
Installing the camera
When attaching the camera to a ceiling bracket or tripod, attach the
supplied tripod adapter. The adapter may be attached to either the top
or bottom of the camera. Use the supplied 1/4" UNC-20 screw to attach
the camera to the tripod or ceiling bracket.
• Use tripod screws and securely tighten then with a driver
• Install the tripod adapter on a flat surface.
SPT-M124
SPT-M124CE
Connections
O
Connect with VIDEO OUT connector.
© Connect with VIDEO IN connector on a video monitor, etc.
0 SPT-M124: to AC 24 V, 60 Hz
SPT-M124CE: to AC 24 V, 50 Hz
SPT-M128CE: to AC 220 - 240 V 50 Hz
SPT-M122CE: to DC 12 V
© 75-ohm coaxial cable
(D Power cable
SPT-M128CE
Q
When using more than one camera, connect to a camera switcher and
set the vertical phase range as follows:
O Camera switcher
© Monitor
Q Vertical phase
© Adjustable range
Vertical phase
|JJ
The picture may roll vertically if the vertical phase is not set To adjust
the vertical phase, turn the V-PHASF adinctnnont