Electrical Connections; Transmitter (Tx); Receiver (Rx) - ABB Orion1 Base Original Instructions Manual

Safety light curtains
Table of Contents

Advertisement

5 Electrical connections

All electrical connections to the transmitter and the receiver are made through a male M12 connector located on the
lower part of the two units, a M12 4-pole connector for the transmitter and a M12-8 pole connector for the receiver.

5.1 Transmitter (TX)

1
Pin
Wire
Function
1
Brown
Supply
2
White
TEST
3
Blue
Supply
4
Black
Not used
1
Colors according to ABB Jokab Safety standard cables

5.2 Receiver (RX)

1
Pin
Wire
Function
RESET/
1
White
ACKNOWLEDGE
2
Brown
Supply
EDM
3
Green
SELECTION
4
Yellow
EDM
5
Grey
OSSD1
6
Pink
OSSD2
7
Blue
Supply
8
Red
RESET MODE
1
Colors according to ABB Jokab Safety standard cables
2TLC172287M0201 Rev B
2015-09-17
Connection to
+24 VDC
NO contact to +24 VDC if to be used
Not connected or 0 V if not to be used
0 V
-
Auto. Reset with no function
Auto. Reset with Acknowledge
function or Alignment mode
Manual Reset
Activate EDM
Deactivate EDM
Function used/activated
Function not used/deactivated
Automatic Reset
Manual Reset
20
Connection to
Not connected or 0 V
NO contact to +24 VDC
NO contact to +24 VDC
+24 VDC
Not connected or 0 V
+24 VDC
NC contact of a force-guided
relay
Not connected or 0 V
Safety control module for ex.
Safety control module for ex.
0 V
Pin 5 (OSSD1)
Pin 6 (OSSD2)
www.abb.com/jokabsafety
Refer to
7.2
Refer to
7.1,
7.3,
6.1
7.4
7.4
7.1

Advertisement