SECTION
3
ELECTRICAL ADJUSTMENTS
NOTE:
e
Adjustment
should be performed 10 minutes after the POWER
switch is on (POWER ON).
VOM
(DC V range)
——
TP1 (L-CH)
|
|
or
TP2 (R-CH)
on AMP
board
Adjustment Location:
[AMP
BOARD]
— Component Side —
RV501
a
Bias Current Adjustment
Procedure :
1. Set main volume to minimum position.
2. Switch on the set.
3. Adjust RV501 (RV601 for right channel) so that
the voltage across
TP1
and TP2
becomes
the
value indicated below.
Adjustment values :
TA-F110
4mV +
TA-F210
2mV
+ 0.3mV