Huawei SUN2000-25KTL-M5 Quick Manual page 5

Hide thumbs Also See for SUN2000-25KTL-M5:
Table of Contents

Advertisement

Pin
Definition
Function
1
GND
2
DIN1
3
DIN2
Ripple control
4
DIN3
5
DIN4
6
DIN5
Rapid shutdown signal+
7
GND
GND
8
-
-
9
485A1
RS485A1 differential signal+
10
485B1
RS485B1 differential signal–
11
485A2
RS485A2 differential signal+
12
485B2
RS485B2 differential signal–
3. Align the pin holes at both ends of the junction box with the positioning pins on the inverter
enclosure to ensure that the screw holes on the junction box are aligned.
4. Install the junction box, seal the unused cable holes in the rubber plugs with waterproof
plugs, and tighten the locking caps.
Description
GND port for the DIN1 to DIN5 signals
Dry contact for grid scheduling
For the rapid shutdown DI signal or connecting
to the signal cable of an NS protective device
-
-
For inverter cascading or connecting to the
RS485 signal port of a SmartLogger
Connecting to the RS485 signal port of a power
meter
4

Advertisement

Table of Contents
loading

Table of Contents