Download Print this page

HANKISON HF-12 Instruction Manual

Compressed air filters

Advertisement

Quick Links

7610.491.1
10/99
INSTRUCTION MANUAL
Corrosion Resistant Models HF(grade)-12
through HF(grade)-36
High Pressure Model HF(grade)-24 and
HF(grade)-32
Contents
MODEL NUMBER CONFIGURATION ..........................
1.0 INSTALLATION ...................................................
2.0 OPERATION .......................................................
3.0 MAINTENANCE .................................................
DIMENSIONS AND WEIGHTS .....................................
REPLACEMENT ELEMENTS .......................................
WARRANTY ..............................................................
General Safety Information
1. Pressurized devices
WARNING
• Do not exceed maximum operating pressure
indicated on serial number tag.
• Make certain filter is fully depressurized before
servicing.
2. Breathing Air
• Air treated by this equipment may not be suitable
for breathing without further purification. Refer
to OSHA standard 1910.134 for breathing air
requirements.
3. Flammable gases
WARNING
While the materials of construction are compatible
with many flammable gases, the following application
limitations must be considered:
• Housing materials are slightly porous. The product
must be used in a well ventilated area in the
absence of sparks or ignition sources. Do not use
in Class 1, Division 1, Group D environments.
• The type of area - forced exhaust system used (i.e.,
high or low level) would be dependent on the gas
involved.
• Each application (other than for air or inert gas)
must be reviewed to minimize fire or explosion
hazard.
2
3
4
5
6
7
8
SERVICE DEPARTMENT: (724) 746-1100
COMPRESSED
AIR
FILTERS
®
1

Advertisement

loading

Summary of Contents for HANKISON HF-12

  • Page 1: Table Of Contents

    7610.491.1 10/99 INSTRUCTION MANUAL ® Corrosion Resistant Models HF(grade)-12 through HF(grade)-36 High Pressure Model HF(grade)-24 and HF(grade)-32 Contents MODEL NUMBER CONFIGURATION ......1.0 INSTALLATION ........... 2.0 OPERATION ............3.0 MAINTENANCE ..........DIMENSIONS AND WEIGHTS ........REPLACEMENT ELEMENTS ........WARRANTY .............. General Safety Information 1.
  • Page 2: Model Number Configuration

    Model Number Configuration Corrosion Resistant Models Filter Grade Housing Bowl Capacity Features 9 - Separator/filter Number Capacity 16 - 16 oz. CR - Corrosion Resistant CR Series scfm Connection Sizes 7 - Air Line Filter 28 - 48 oz. S - 304 Stainless Steel /min] @ 5 - High Efficiency Oil Removal Filter Element...
  • Page 3: Installation

    1.0 Installation A. Where Used/Air Quality After Filtration Grade Where used Solid particle Liquid removal Maximum inlet Remaining oil removal (maximum efficiency (at rated liquid loading content size in microns) conditions) ppm w/w ppm w/w Separator - downstream of an 99+% of water 25,000 aftercooler...
  • Page 4: Operation

    2.0 Operation 4. Check that manual drains are drained periodically or that automatic drains are functioning. WARNING: Do not operate filter at pressures in excess of Grade 1 Maximum Working Pressure indicated on Serial Number Tag. 1. Check for an oily smell by opening the manual valve. If an oily smell exists, the following should be checked: NOTE: Maximum Operating Temperature - 150°F, 66°C.
  • Page 5: Maintenance

    3.0 Maintenance 1) Unscrew the old filter element and discard. Also discard the small o-ring that seals the filter to A. When to Replace Filter Element the filter assembly head. NOTE: Grades 7,5,3,1 - complete element is replaced; 2) Insert small replacement o-ring on top of Grade 9 - unless separator core is damaged outer sleeve replacement filter element and screw only is replaced.
  • Page 6: Dimensions And Weights

    Dimensions and Weights Models In/Out Bowl Type Dimensions in. (mm) Weights Connections* lbs (kg) 03 or 04 3-3/16 9-3/8 2-3/4 3/8" or 1/2" 16 oz. Metal (81) (254) (238) (102) (1.24) 03 or 04 3-3/16 9-3/8 2-3/4 3/8" or 1/2" 16 oz.
  • Page 7: Replacement Elements

    Replacement Elements High Pressure Model Element* Model Element* HF9-24-8-62 E9-24-07** HF9-32-8-62 E9-32-11** HF7-24-8-62 E7-24-08 HF7-32-8-62 E7-32-10 HF5-24-8-62 E5-24-08 HF5-32-8-62 E5-32-10 HF3-24-8-62 E3-24-08 HF3-32-8-62 E3-32-10 HF1-24-8-62 E1-24-08 HF1-32-8-62 E1-32-10 *Add S to element number for 304SS elements (eg. E9-24S-07). *Add S to element number for 304SS elements **Sleeve only: S9-24 or S9-24S for 304SS.
  • Page 8: Warranty

    WARRANTY The manufacturer warrants the product manufactured by it, when properly installed, operated, applied, and maintained in accordance with procedures and recommendations outlined in manufacturer’s instruction manuals, to be free from defects in material and workmanship for a period of one (1) year from date shipment to the buyer by the manufacturer or manufacturer’s authorized distributor provided such defect is discovered and brought to the manufacturer’s attention within the aforesaid warranty period.

This manual is also suitable for:

Hf-36Hf-24Hf-32Hf-16Hf-28Hf9-24-8-62 ... Show all