Black & Decker BPP06WTB Manual
Hide thumbs Also See for BPP06WTB:

Advertisement

Quick Links

PORTABLE AIR CONDITIONER
INSTRUCTION MANUAL
CATALOG NUMBER
BPP05WTB
BPP06WTB
BPP08WTB
BPP08HWTB
BPP10WTB
BPP10HWTB
Thank you for choosing BLACK+DECKER!
PLEASE READ BEFORE RETURNING THIS PRODUCT FOR
ANY REASON.
If you have a question or experience a problem with your BLACK+DECKER
purchase, go to www.blackanddecker.com/instantanswers
If you can't find the answer or do not have access to the Internet, call
844-299-0879 from 10:30 a.m. to 6:30 p.m. EST Mon. - Fri. to speak with an
agent. Please have the catalog number available when you call.
SAVE THIS MANUAL FOR FUTURE REFERENCE.

Advertisement

Table of Contents
loading

Summary of Contents for Black & Decker BPP06WTB

  • Page 1 PORTABLE AIR CONDITIONER INSTRUCTION MANUAL CATALOG NUMBER BPP05WTB BPP06WTB BPP08WTB BPP08HWTB BPP10WTB BPP10HWTB Thank you for choosing BLACK+DECKER! PLEASE READ BEFORE RETURNING THIS PRODUCT FOR ANY REASON. If you have a question or experience a problem with your BLACK+DECKER purchase, go to www.blackanddecker.com/instantanswers If you can’t find the answer or do not have access to the Internet, call...
  • Page 2: Table Of Contents

    ENGLISH CONTENTS SAFETY INFORMATION Important Safety Instructions ............................3-4 Grounding Instructions ................................. 5 LCDI Power Cord and Plug ..............................6 Safety Guidelines ..............................8 SET UP & USE Parts & Features ..................................9 Specifications ................................. 10 Installation Guide ..............................10 Window Slider Kit Installation ..........................11 Exhaust Hose Installation ............................12 Control Panel ................................13 Operating from the Control Panel ......................
  • Page 3: Safety Information

    ENGLISH SAFETY INFORMATION DANGER WARNING CAUTION DANGER - Immediate hazards WARNING - Hazards or unsafe CAUTION - Hazards or unsafe which WILL result in severe practices which COULD result in practices which COULD result in personal injury or death severe personal injury or death minor personal injury IMPORTANT SAFETY INSTRUCTIONS WARNING...
  • Page 4 ENGLISH SAFETY INFORMATION HANDLING ALKALINE BATTERIES WARNING When handling alkaline batteries, basic safety precautions should be followed, including the following Should fluid from the battery accidentally get into your eyes, there is a threat of loss of eyesight, do not rub them. Immediately rinse your eyes with clean tap water and then consult a physician immediately.
  • Page 5: Grounding Instructions

    ENGLISH SAFETY INFORMATION GROUNDING INSTRUCTIONS ELECTRICAL REQUIREMENTS In the event of malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. The appliance must be connected to a cord having an equipment- grounding conductor and a grounding plug.
  • Page 6: Lcdi Power Cord And Plug

    ENGLISH SAFETY INFORMATION LCDI POWER CORD AND PLUG This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord that is required by UL. This power supply cord contains state-of-the-art electronics that sense leakage current. If the cord is damaged and leakage occurs, power will be disconnected from the unit.
  • Page 7: Safety Guidelines

    ENGLISH SAFETY INFORMATION SAFETY GUIDELINES To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. ALWAYS DO THIS NEVER DO THIS ENERGY SAVE •...
  • Page 8 ENGLISH SAFETY INFORMATION OPERATING CONDITION The air conditioner must be operated within the temperature range indicated below: NOTE: · Unit performance may be affected when in use outside of these operating temperatures. MODE ROOM TEMPERATURE COOL 64˚F (18˚C) ~ 95˚F (35˚C) DEHUMIDIFY 64˚F (18˚C) ~ 95˚F (35˚C) HEAT (ELECTRICAL HEAT TYPE)
  • Page 9: Set Up & Use

    ENGLISH SET UP & USE PARTS & FEATURES Dehumidification Louver Control Panel Filter Drain Front Panel Power Cord Air Exhaust Castors (4) Hose Housing Condensation Drain Hose outlet and inlet are pre-assembled to the hose Air Exhaust Hose Hose Outlet Hose Inlet Connects to Connects to...
  • Page 10: Specifications

    SPECIFICATIONS BPP05WTB Unit dimensions (W x D x H): 17.32” x 14.05” x 27.16” Unit Weight approx. 51.1 lbs. BPP06WTB Unit dimensions (W x D x H): 17.32” x 14.05” x 27.16” Unit Weight approx. 54.8 lbs. BPP08WTB Unit dimensions (W x D x H): 17.32” x 14.05” x 27.16”...
  • Page 11: Window Slider Kit Installation

    ENGLISH SET UP & USE WINDOW SLIDER KIT INSTALLATION Your window slider kit has been designed to fit most standard “Vertical” and “Horizontal” window applications; however, it may be necessary for you to improvise/modify some aspect of the installation procedures for certain types of window.
  • Page 12: Exhaust Hose Installation

    ENGLISH SET UP & USE EXHAUST HOSE INSTALLATION The air exhaust hose and hose inlet must be installed or removed from the portable air conditioner in accordance with the way it is being used: COOL, DEHUMIDIFY, HEAT (Heat models BPP08HWTB and BPP10HWTB only: Air exhaust hose and hose inlet should be connected to the portable air conditioner.
  • Page 13: Control Panel

    ENGLISH SET UP & USE CONTROL PANEL Swing Indicator Light Fan Speed FULL Tank Select Mode Indicator Lights Sleep Indicator Indicator Heat models BPP08HWTB Indicator light and BPP10HWTB only Lights Light Display Area Timer Indicator Timer Fan Speed Power Mode Decrease Increase Light...
  • Page 14 ENGLISH SET UP & USE DEHUMIDIFICATION MODE COOL MODE Ideal for hot weather when • It is recommended that the you need to cool the room. dehumidification drain and drain To set operation of the appliance hose can be used for continuous correctly, press the + or –...
  • Page 15 ENGLISH SET UP & USE TIMER SWING INDICATOR LIGHT When this light is illuminated, it • To set the AUTO STOP timer. When indicates that the air swing is activated the unit is ON, press the TIMER from the remote and the louvers will button.
  • Page 16: Operating From The Remote Control

    ENGLISH SET UP & USE OPERATING FROM THE REMOTE CONTROL BATTERY INSTALLATION (BATTERIES NOT INCLUDED) (1) Slide open the battery compartment cover. (2) Insert 2 × “AAA”batteries as shown. (3) Slide back the battery cover. CAUTION: Use only AAA or IEC R03 1.5V alkaline batteries. Remove the batteries if the remote is not used for a month or longer.
  • Page 17 ENGLISH SET UP & USE REMOTE CONTROL Dehumidify Cool Remote Signal Heat Fan Speed Swing Sleep Time Time ON / OFF Increase Button °F /°C Selector LED Button Button Decrease Button Mode Button Swing Button Fan Speed Timer Button Button Sleep Button Power Button POWER BUTTON: Press to Turn ON or OFF...
  • Page 18 ENGLISH SET UP & USE LED Display Indicators Cooling mode Fan speed Dehumidify mode Swing Fan mode Timer on Heat mode Time Heat models BPP08HWTB and Sleep BPP10HWTB only Display temp. or Fahrenheit or hours Celsius. POWER BUTTON • Press to Turn Air Conditioner ON or OFF. Press LED button to illuminate the LED screen on the unit.
  • Page 19 ENGLISH SET UP & USE DEHUMIDIFY Ideal for reducing humidity. • Keep window and door closed for the best dehumidifying effect. • Exhaust hose attachment is not required to reduce humidity, however it is recommended in very humid rooms so the warm air can be exhausted outside. Draining in Dehumidify mode •...
  • Page 20 ENGLISH SET UP & USE TIMER • To set the AUTO STOP timer. When the unit is ON, press the TIMER button. The TIME ON/OFF symbol on the remote LCD display will blink. • Press the + or – button to select the AUTO TIME by 1 hour increments, up to 24 hours.
  • Page 21: Water Drainage

    ENGLISH SET UP & USE WATER DRAINAGE FOR COOLING AND HEAT MODES This air conditioner is equipped with auto water evaporation so the water compartment would not typically fill in cooling or heating mode unless there is high humidity. Water drainage will generally only be required at the end of the season for these modes.
  • Page 22 ENGLISH SET UP & USE Continuous Draining for Dehumidification Mode Unplug the unit from the power source. Remove the drain cap located in the back center of the unit. While doing this operation some residual water may spill so have a drip pan (not supplied) to collect the water.
  • Page 23: Cleaning & Care

    ENGLISH CLEANING & CARE CLEANING WARNING: Before cleaning or maintenance, turn the appliance off by pressing the button on the control panel or button on the remote control. Unplug from the electrical outlet. CLEANING THE CABINET You should clean the appliance with a slightly damp cloth then dry with a dry cloth.
  • Page 24: Troubleshooting & Warranty

    ENGLISH TROUBLESHOOTING & WARRANTY BEFORE YOU CALL FOR SERVICE IF THE AIR CONDITIONER FAILS TO OPERATE: A) Check to make sure that the air conditioner is plugged in securely. If it is not, remove the plug from the outlet, wait 10 seconds and plug it in again securely.
  • Page 25: Troubleshooting

    ENGLISH TROUBLESHOOTING & WARRANTY Troubleshoot your problem by using the chart below. If the air conditioner still does not work properly, contact BLACK+DECKER customer service center or the nearest authorized service center. Customers must never troubleshoot internal components. TROUBLE POSSIBLE CAUSE POSSIBLE REMEDY Unit does not start when A.
  • Page 26: Limited Warranty

    ENGLISH TROUBLESHOOTING & WARRANTY LIMITED WARRANTY Any repair, replacement, or warranty service, REPAIR OR REPLACEMENT AS PROVIDED UNDER THIS WARRANTY IS THE EXCLUSIVE REMEDY OF and all questions about this product should be THE CUSTOMER; BLACK+DECKER. SHALL NOT BE directed to BLACK+DECKER at 844-299-0879 LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL from the USA or Puerto Rico.
  • Page 27 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules.