Download Print this page

Honeywell ZW3004 Installation Instructions

Smart dimmer in-wall

Advertisement

Quick Links

FCC/IC - EN
This device complies with Part 15 of the FCC and Industry Canada license-exempt
RSS standards. Operation is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
FCC NOTE: The manufacturer is not responsible for any radio or TV
interference caused by unauthorized modifications to this equipment. Such
modifications could void the user's authority to operate the equipment
NOTE: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy, and if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different to which the receiver is connected.
— Consult the dealer or an experienced radio/TV technician for help.
Important note: To comply with the FCC RF exposure compliance requirements,
no change to the antenna or the device is permitted. Any change to the
antenna or the device could result in the device exceeding the RF exposure
requirements and void user's authority to operate the device.
FCC /IC - FR
Cet appareil est conforme au paragraphe 15 des normes FCC et au CNR pour les
appareils exempts de licence d'Industrie Canada. Son utilisation est sujette aux
deux conditions suivantes (1) cet appareil ne doit pas occasionner de brouillage
préjudiciable et (2) cet appareil doit accepter toutes les interférences reçues,
notamment les interférences qui peuvent provoquer un fonctionnement non désiré.
REMARQUE DE LA FCC : Le fabricant n'est pas responsable des interférences
sur les fréquences radioélectriques ou télévisuelles pouvant être causées
par des modifications non autorisées de ce matériel. De telles modifications
peuvent annuler le droit de l'utilisateur à utiliser cet appareil.
REMARQUE : Cet appareil a été testé et certifié conforme aux limites relatives aux appareils
numériques de catégorie B définies dans le paragraphe 15 des normes FCC. Ces limites ont
été définies afin de fournir une protection raisonnable contre le brouillage préjudiciable en
milieu résidentiel. Cet appareil produit, utilise et peut émettre des ondes de fréquence radio et,
s'il n'est pas installé et utilisé conformément aux instructions, il peut provoquer un brouillage
préjudiciable aux communications radio. Il n'existe toutefois aucune garantie que des
interférences ne se produiront pas dans une installation donnée. Si cet appareil occasionne
un brouillage préjudiciable à la réception radiophonique ou télévisuelle, il suffit d'allumer
et d'éteindre l'appareil pour déterminer sa responsabilité. Nous encourageons l'utilisateur à
essayer de corriger ces interférences en appliquant une ou plusieurs des mesures suivantes :
— Réorienter ou déplacer l'antenne de réception.
— Augmenter la distance entre l'appareil et le récepteur.
— Brancher l'appareil à une prise secteur différente de celle du récepteur.
— Pour obtenir de l'aide, consulter le revendeur ou un technicien
spécialisé en postes radio ou téléviseurs.
Remarque importante : Pour se conformer aux exigences de conformité de la
FCC concernant l'exposition aux RF, aucune modification apportée à l'antenne
ou au dispositif n'est autorisée. Toute modification apportée à l'antenne ou au
dispositif pourrait faire en sorte que le dispositif dépasse les exigences d'exposition
aux RF et pourrait annuler le droit de l'utilisateur à utiliser ce dispositif.
FCC/IC - ES
Este dispositivo cumple con las Especificaciones del apartado 15 de las normas de
la FCC y con las especificaciones de las normas radioeléctricas (RSS) del Ministerio
de Industria de Canadá aplicables a aparatos exentos de licencia. El funcionamiento
está sujeto a las siguientes dos condiciones: (1) este dispositivo no debe provocar
interferencia perjudicial, y (2) este dispositivo debe aceptar toda interferencia
que reciba, incluso la que pudiera causar un funcionamiento no deseado.
NOTA DE LA FCC: El fabricante no se hace responsable de ninguna interferencia de
radio o TV ocasionada por modificaciones no autorizadas efectuadas a este equipo.
Dichas modificaciones podrían anular la autoridad del usuario para utilizar el equipo.
NOTA: Este equipo ha sido probado y cumple con los límites para aparatos digitales
de Clase B, de conformidad con el apartado 15 de las normas de la FCC. Estos límites
están diseñados para proveer protección razonable contra interferencias perjudiciales
en una instalación residencial. Este equipo genera, usa y puede irradiar energía de
radiofrecuencias y, si no se instala y usa según las instrucciones, puede provocar
interferencia perjudicial a las radiocomunicaciones. No obstante, no hay garantías de
que no ocurrirá interferencia en una instalación en particular. Si este equipo provoca
interferencia perjudicial a la recepción de radio o televisión, lo que puede determinarse
encendiendo y apagando el equipo, se recomienda que el usuario intente corregir la
interferencia por medio de la implementación de una o más de las siguientes medidas:
— Reorientar o reubicar la antena receptora.
— Incrementar la separación entre el equipo y el receptor.
— Conectar el equipo a un tomacorriente de un circuito diferente
del circuito al que está conectado el receptor.
— Consultar al distribuidor o a un técnico con experiencia en radio/televisión para
solicitar asistencia.
Nota importante: Para cumplir con los requisitos de cumplimiento de exposición de
radiofrecuencia de la FCC, no se permiten cambios a la antena o el dispositivo. Cualquier
cambio a la antena o dispositivo podría hacer que el dispositivo supere los requerimientos de
exposición de radiofrecuencia y anular la autoridad del usuario para operar el dispositivo.
Responsible Party - US Contact Information | Parte responsable - Información de contacto
de los Estados Unidos | Partie responsable - Coordonnées des États-Unis
FCC — U2ZZW3004A | IC: 6924A-ZW3004A
Jasco Products Company | Model:
ZW3004/39357
10 E. Memorial Rd., Oklahoma City, OK 73114 | 1-800-654-8483
CAN ICES-3(B)/NMB-3(B)
All brand names shown are
Tous les noms de marque illustrés
Todas las marcas que aparecen
trademarks of their respective owners.
sont des marques de commerce
aquí son marcas registradas
de leurs propriétaires respectifs.
de sus respectivos dueños
The Honeywell Trademark is used under license
from Honeywell International Inc.
Honeywell International Inc. makes no representation or warranties with
respect to this product.
This product is manufactured by Jasco Products Company LLC.
MADE IN CHINA/FABRIQUÉ EN CHINE/HECHO EN CHINA
©JASCO 2019 | 39357 | ZW3004 | 06/05/19 v1
Jasco Products Company LLC.
10 E. Memorial Rd.,
Oklahoma City, OK 73114
1
TOOLS
IMPORTANT!
The fixture controlled by the Z-Wave In-Wall Dimmer must not exceed 600W (incandescent);
150W dimmable CFL/LED. The dimmer is designed only for use with permanently
installed fixtures.
2
FEATURES
Turn ON/OFF and adjust dim levels manually or remotely via the
Z-Wave controller
Can be included in multiple groups and scenes
May be used in single-pole installation or with up to two Honeywell
Add-on Switches in 3-way or 4-way wiring configurations
Compatible with all incandescent and most dimmable CFL/LED bulbs
Uses a standard toggle wallplate for single-gang installations
(wallplate not included)
Z-Wave certified for simple pairing and integrated home automation
Screw terminal installation — requires wiring connections for line
(hot), load, neutral, and ground. Traveler wire required for 3-way or
4-way installation
This Z-Wave device has advanced features that allow you to customize
your experience. These features can only be adjusted by a Z-Wave
enabled controller that supports the Z-Wave configuration command
class. For a complete list of adjustable configurations,
visit www.honeywellelectricalaccessories.com
A
D
B
F
G
E
C
A.
Ground (Green/Bare)
F.
UP — Press & release to turn
dimmer ON, press & hold to
B.
Load (Black)
increase brightness
C.
Line (Black)
G.
Down — Press & release to
D.
Traveler (Red/Other)
turn dimmer OFF, press &
E.
Neutral (White)
hold to dim
READ IT OR WATCH IT
Read instructions or watch easy-to-follow
video. Scan QR code or visit goo.gl/BQF7Xd
SMART DIMMER
IN-WALL
GRADATEUR INTELLIGENT
MURAL
ATENUADOR DE LUZ INTELIGENTE
PARA PARED
Z-W
® C
W
l
C
ave
ertified
ireless
ighting
ontrol
Z-W
® C
i
i
ave
ontrol de
luminaCión
nalámbriCo CertifiCado
C
Z-W
®
ontrol inalámbriCo para iluminaCión CertifiCado por
ave
Purchase additional items at
Purchase additional items at
Purchase additional items at
honeywellelectricalaccessories.com
honeywellelectricalaccessories.com
honeywellelectricalaccessories.com
or visit your local retailer.
or visit your local retailer.
or visit your local retailer.
In-Wall
In-Wall
In-Wall
Plug-in
Plug-in
Plug-in
Smart Switches
Smart Switches
Smart Switches
Smart Swtiches
Smart Swtiches
Smart Swtiches
Plug-in
Plug-in
Plug-in
In-Wall
In-Wall
In-Wall
Smart Dimmers
Smart Dimmers
Smart Dimmers
Smart Dimmers
Smart Dimmers
Smart Dimmers
In-Wall
In-Wall
In-Wall
Plug-in
Plug-in
Plug-in
Smart Fan Control
Smart Fan Control
Smart Fan Control
Outdoor
Outdoor
Outdoor
Smart Switch
Smart Switch
Smart Switch
In-Wall
In-Wall
In-Wall
In-Wall
In-Wall
In-Wall
Add-on Switches
Add-on Switches
Add-on Switches
Tamper-Resistant
Tamper-Resistant
Tamper-Resistant
Smart Outlet
Smart Outlet
Smart Outlet
3
INSTALLATION
1
1
2
3
OUT TO
LIGHT (LOAD)
B
A
D
E
C
5
7
FROM BREAKER BOX
out to light (load)
A
B
D
E
C
from breaKer boX
8
9
10 11
12 13
14
DO NOT RETURN THIS
PRODUCT TO THE STORE
NE RETOURNEZ PAS
STOP
CE PRODUIT AU MAGASIN
NO DEVUELVA ESTE
PRODUCTO A LA TIENDA
If you have any problems or questions, contact our tech support
team at 1-855-698-8324, Monday–Friday, 7AM–8PM CST.
For the most up-to-date product support, accessories, electronic
(PDF) format manuals and more, visit www.byjasco.com/support.
• No user serviceable parts in this unit.
Si vous avez des problèmes ou des questions, communiquez
avec notre équipe de soutien technique au 1-855-698-8324,
option 1, du lundi au vendredi, de 7 h à 20 h (HNC).
Pour le soutien relatif aux produits le plus à jour, les
accessoires, les manuels en format électronique (PDF) et
plus encore, visitez le site www.byjasco.com/support.
• Aucune des pièces de ce dispositif ne peut être réparée par l'utilisateur.
Si tiene problemas o dudas, comuníquese con nuestro equipo
técnico al número: 1-855-698-8324, opción 1 de lunes a viernes,
de 7 a.m. a 8 p.m., hora estándar del centro (CST).
Para recibir el soporte técnico más actualizado sobre productos, accesorios,
manuales en formato digital (PDF), entre otros, visite www.byjasco.com/support.
• Esta unidad no contiene piezas que el usuario pueda reparar.
WARNING
ADVERTENCIA
RISK OF FIRE
RIESGO DE INCENDIO
RISK OF ELECTRICAL SHOCK
RIESGO DE DESCARGA ELÉCTRICA
RISK OF BURNS
RIESGO DE QUEMADURAS
CONTROLLING APPLIANCES
CONTROL DE EQUIPOS
CAUTION: TO REDUCE THE RISK OF
ELECTRODOMÉSTICOS
OVERHEATING AND POSSIBLE DAMAGE
PRECAUCIÓN: A FIN DE DISMINUIR
TO OTHER EQUIPMENT, DO NOT
EL RIESGO DE RECALENTAMIENTO
INSTALL TO CONTROL A RECEPTACLE,
Y DE POSIBLES DAÑOS EN LOS
A MOTOR-OPERATED APPLIANCE, A
DEMÁS EQUIPOS, NO INSTALAR
FLUORESCENT LIGHTING FIXTURE, OR A
PARA CONTROLAR APARATOS QUE
TRANSFORMER-SUPPLIED APPLIANCE
FUNCIONAN A MOTOR, ARTEFACTOS DE
ONLY USE TO CONTROL INCANDESCENT
ILUMINACIÓN DE LUZ FLUORESCENTE
O APARATOS ALIMENTADOS
OR DIMMABLE CFL/LED BULBS
39357
CON TRANSFORMADORES
DO NOT EXCEED RATINGS
ZW3004
USAR EXCLUSIVAMENTE PARA
DO NOT USE TO CONTROL ANY DEVICE
CONTROLAR BOMBILLAS CFL/LED
WHERE UNINTENDED OPERATION
INCANDESCENTES O ATENUABLES
COULD CAUSE UNSAFE CONDITIONS
NO SUPERE LOS VALORES
(HEAT LAMP, SUN LAMP, ETC.)
NOMINALES ELÉCTRICOS
FOR INDOOR USE ONLY
NO USAR PARA CONTROLAR
DISPOSITIVOS
AVERTISSEMENT
USE SOLAMENTE EN INTERIORES
RISQUE D'INCENDIE
NOT FOR USE WITH MEDICAL OR
RISQUE DE CHOC ÉLECTRIQUE
LIFE-SUPPORT EQUIPMENT
RISQUE DE BRÛLURES
Z-WAVE ENABLED DEVICES SHOULD
NEVER BE USED TO SUPPLY POWER TO,
COMMANDE DES APPAREILS
OR CONTROL THE ON/OFF STATUS OF
ATTENTION: POUR RÉDUIRE LE RISQUE
MEDICAL OR LIFE-SUPPORT EQUIPMENT.
DE SURCHAUFFE ET DE DOMMAGES
POSSIBLES À D'AUTRES APPAREILS, NE
NE PAS UTILISER AVEC UN
PAS INSTALLER POUR COMMANDER
UN APPAREIL ACTIONNÉ PAR
ÉQUIPEMENT MÉDICAL
MOTEUR, UN APPAREIL D'ÉCLAIRAGE
OU DE SURVIE
FLUORESCENT OU UN APPAREIL
LES DISPOSITIFS COMPATIBLES
ALIMENTÉ PAR UN TRANSFORMATEUR
AVEC LA TECHNOLOGIE Z-WAVE NE
DEVRAIENT JAMAIS ÊTRE UTILISÉS
UTILISER SEULEMENT POUR
COMMANDER LES AMPOULES À DEL ET
POUR ALIMENTER OU COMMANDER
LA MISE EN MARCHE OU L'ARRÊT DE
FLUOCOMPACTES À INCANDESCENCE
OU À INTENSITÉ RÉGLABLE
L'ÉQUIPEMENT MÉDICAL OU DE SURVIE.
NE PAS DÉPASSER LES
CARACTÉRISTIQUES NOMINALES
SE PROHÍBE SU EMPLEO EN
NE PAS UTILISER POUR COMMANDER
EQUIPO MÉDICO O EQUIPO
DES APPAREILS POUR LESQUELS
PARA EL MANTENIMIENTO DE
UN FONCTIONNEMENT IMPRÉVU
LAS FUNCIONES VITALES
POURRAIT ENTRAÎNER DES CONDITIONS
LOS DISPOSITIVOS Z-WAVE NUNCA
DANGEREUSES (LAMPE À RAYONS
SE DEBEN USAR PARA SUMINISTRAR
INFRAROUGES, LAMPE SOLAIRE, ETC.)
ENERGÍA ELÉCTRICA AL EQUIPO MÉDICO
POUR UTILISATION INTÉRIEURE
O AL EQUIPO PARA EL MANTENIMIENTO
UNIQUEMENT
DE FUNCIONES VITALES, NI PARA
CONTROLAR EL ESTADO DE ENCENDIDO
O APAGADO DE DICHOS EQUIPOS.
WARNING — SHOCK HAZARD
Turn OFF the power to the branch circuit for the switch and lighting fixture at the service
panel. All wiring connections must be made with the POWER OFF to avoid personal injury
and/or damage to the dimmer. This device is intended for installation in accordance with the
National Electric Code and local regulations in the United States, or the Canadian Electrical
Code and local regulations in Canada. If you are unsure or uncomfortable about performing
this installation, consult a qualified electrician.
MULTI-SWITCH WIRING
The Honeywell Add-on Switch is required for multi-switch 3-way or 4-way
installations. Connecting the traveler terminal of this switch to a standard,
non-Honeywell switch will cause damage or result in improper function. If this
switch is a part of a 3-way or 4-way multi-switch installation, do not connect
the traveler wire or apply power until Honeywell Add-on Switches are correctly
installed. For more information on 3-way or 4-way installations, view the
manual or quick-start guide that comes with the Honeywell Add-on Switch.
IMPORTANT! Verify power is OFF to switch box before continuing.
SINGLE-SWITCH WIRING
1.
Shut off power to the circuit at circuit breaker or fuse box.
IMPORTANT! Verify power is OFF to switch box before continuing.
2.
Remove wallplate.
3.
Remove the switch mounting screws.
4.
Carefully remove the switch from the switch box. DO NOT disconnect
the wires.
5.
There are up to five screw terminals on the switch; these are marked:
A. GROUND — Green/Bare
B. LOAD — Black (connected to lighting)
C. LINE (Hot) — Black (connected to power)
D. TRAVELER — Red/Other (only in 3-way installations)
E. NEUTRAL — White
Match these screw terminals to the wires connected to the existing switch.
6.
Disconnect the wires from the existing switch. Label wires according to
the previous terminal connection.
OBSERVE IMPORTANT WIRING INFORMATION
IMPORTANT! This dimmer is rated for and intended to only be used with copper wire.
WIRE GAUGE REQUIREMENTS
Use 14AWG or larger wires suitable for at least 80° C for supplying line (hot),
load, neutral, ground and traveler connections.
WIRE STRIP LENGTH
7.
For attachment to screw terminals, strip insulation 1in. (25mm).
For attachment using the enclosure's holes, strip insulation 5/8in. (16mm).
UL specifies that the tightening torque for the screws is
14 Kgf-cm (12 lbf-in).
8.
Connect the green or bare copper ground wire to the GROUND
terminal.
9.
Connect the black wire from the light to the terminal marked LOAD.
10.
Connect the black wire from the electrical service panel (Hot) to the
terminal marked LINE.
11.
Connect the white wire to the neutral terminal (use a jumper wire if needed).
Note: The traveler terminal is only used for 3-way or 4-way
wiring and should remain insulated if the switch is being
installed in a 2-way system (one switch & one load).
12.
Insert dimmer into the switch box being careful not to pinch or crush wires.
13.
Secure the dimmer to the box using the supplied screws.
14.
Mount the wallplate.
15.
Reapply power to the circuit at fuse box or circuit breaker and test
the system.
BASIC OPERATION
The connected light can be turned ON/OFF and adjust dim level in two ways:
1.
Manually from the front panel of the in-wall dimmer.
2.
Remotely with a Z-Wave controller.
MANUAL CONTROL
The front panel toggle switch allows the user to turn ON/OFF the
connected fixture.
To turn the connected fixture ON, press and release up on the toggle.
To turn the connected fixture OFF, press and release down on the toggle.
ADJUST DIM LEVEL
1.
To increase brightness, press and hold up on the toggle.
2.
To decrease brightness, press and hold down on the toggle.
NOTE: Actual performance of any CFL or LED will vary from bulb type to bulb type and among
different manufacturers. It is important to note only bulbs designed as dimmable should be used
with a dimmer. To find out if your bulb is dimmable, please check the package, the bulb itself or call
the a bulb manufacturer directly.
For a complete list of recommended CFL/LED bulbs for this and other Z-Wave products, please
visit www.honeywellelectricalaccessories.com.
WARRANTY
Jasco Products warrants this product to be free from manufacturing defects for two
years from the original date of consumer purchase. This warranty is limited to the repair
or replacement of this product only and does not extend to consequential or incidental
damage to other products that may be used with this product. This warranty is in lieu
of all other warranties, expressed or implied. Some states do not allow limitations on
how long an implied warranty lasts or permit the exclusion or limitation of incidental
or consequential damage, so the above limitations may not apply to you. This warranty
gives you specific rights and you may also have other rights which vary from state to
state. Please contact Customer Service at 1-855-698-8324 between 7AM – 8PM CST
or via www.byjasco.com if the unit should prove defective within the warranty period.
GARANTIE
Jasco Products garantit que ce produit est exempt de tout défaut de fabrication pour une
période de deux ans à compter de la date de l'achat original par l'acheteur. Cette garantie
se limite exclusivement à la réparation ou au remplacement de ce produit et n'est pas
applicable aux dommages indirects ou accessoires survenus sur d'autres produits utilisés
avec ce produit. Cette garantie se substitue à toute autre garantie expresse ou implicite.
Certains États ne permettent pas de restrictions quant à la durée d'une garantie implicite
ou permettent l'exclusion ou la limitation des dommages indirects et accessoires; il se
peut, par conséquent, que cette garantie ne s'applique pas dans votre cas. Cette garantie
vous confère des droits juridiques précis; vous pouvez jouir d'autres droits qui peuvent
varier d'un État à l'autre. Veuillez communiquer avec le service à la clientèle au 1-855-
698-8324 entre 7 h et 20 h (heure normale du Centre) ou par l'intermédiaire de notre site
web (www.byjasco.com) si l'appareil s'avère défaillant au cours de la période de garantie.
GARANTÍA
Jasco Products garantiza que este producto está libre de defectos de fabricación durante
un periodo de dos años a partir de la fecha original de compra por parte del consumidor.
Esta garantía se limita a la reparación o sustitución de este producto solamente y no se
extiende a daños derivados o accidentales causados a otros productos que se usen con
esta unidad. Esa garantía remplaza a todas las demás garantías expresas o implícitas.
Algunos estados no autorizan limitaciones en cuanto a la duración de una garantía
implícita ni permiten la exclusión o limitación por daños accidentales o derivados; por
lo tanto, puede que las anteriores limitaciones no apliquen en su caso. Esta garantía le
da a usted derechos específicos, y otros que usted puede tener y que varían según el
estado en el que usted reside. Si la unidad resultare defectuosa dentro del periodo de
garantía, comuníquese por favor con Atención al Cliente en el 855-698-8324 entre 7
y 20 h, Hora del Centro, o a través de nuestro sitio de internet (www.byjasco.com).
Jasco Products Company LLC, Building B
10 E. Memorial Rd. Oklahoma City, OK 73114.
SPECIFICATIONS
ZW3004
Power: 120VAC, 60Hz.
Signal (Frequency): 908.4/916MHz
Maximum Loads: 600W, 2-gang 500W or 3-gang 400W incandescent/150W CFL/LED
Range: Up to 150ft. line of sight between the wireless controller
and the closest Z-Wave receiver module.
Operating Temperature Range: 32-104° F (0-40° C)
For indoor use only.
Specifications subject to change without notice due to continuing product improvement.
SPÉCIFICATIONS
ZW3004
Tension : 120VCA., 60Hz.
Signal (fréquence) : 908.4/916MHz
Charges maximales : 600W, 2 compartiments 500W,
3 compartiments 400W lampes à incandescent/150W CFL/LED
Portée : Distance à vue entre la télécommande et le module de
réception Z-Wave le plus proche allant jusqu'à 150 pi.
Plage de températures de fonctionnement : de 32 à 104° F (de 0 à 40° C).
Utilisation intérieure uniquement.
En raison d'améliorations continues du produit, les spécifications
peuvent faire l'objet de changements sans préavis.
ESPECIFICACIONES
ZW3004
Energía: 120VCA, 60Hz.
Señal (Frecuencia): 908.4/916MHz
Cargas máximas: 600W, Caja para 2 conexiones 500W,
Caja para 3 conexiones 400W sólo las lámparas incandescente 150 CFL/LED
Alcance: Hasta 150 pies en línea de visión directa entre el control
remoto inalámbrico y el módulo receptor Z-Wave más cercano.
Rango de temperatura de funcionamiento: 32-104° F (0-40°C).
Para uso en espacios interiores solamente.
Especificaciones sujetas a cambio sin aviso debido a continuas mejoras del producto
Z-WAVE INTEROPERABILITY
This product can be included and operated in any Z-Wave network with
other Z-Wave certified devices from other manufacturers and/or other
applications. All non-battery operated nodes within the network will act as
repeaters regardless of vendor to increase reliability of the network.
INTEROPÉRABILITÉ ENTRE LES DISPOSITIFS Z-WAVE
Ce produit peut être utilisé dans un réseau Z-Wave avec d'autres appareils
certifiés Z-Wave produits par d'autres fabricants et d'autres applications. Tous les
nœuds fonctionnant sans pile au sein du réseau joueront le rôle de répétiteurs,
quel que soit le fournisseur, afin de rehausser la fiabilité du réseau.
INTEROPERABILIDAD Z-WAVE
Este producto se puede incluir y puede funcionar en cualquier red Z-Wave con dispositivos
de otros fabricantes y otras aplicaciones que cuenten con la certificación Z-Wave. Todos
los nodos que formen parte de la red y que funcionen sin pilas actuarán de repetidores
independientemente del proveedor con el fin de aumentar la fiabilidad de la red.
4
CONNECTION
CONNECTING YOUR DEVICE TO A Z-WAVE NETWORK
1.
Follow the instructions for your Z-Wave certified controller to add a
device to the Z-Wave network.
2.
Once the controller is ready to add your device, press up and release
the toggle.
If prompted by the controller to enter the S2 security code, refer to the
QR code/security number on the back of the box, or the QR code label
on the product.
DSK :
XXXXX
-125651-22671
-26939-47599
-19612-25872
-47752
Now, you have complete control to turn your fixture ON/OFF and adjust
brightness according to groups, scenes, schedules and interactive
automations programmed by your controller. If your Z-Wave certified
controller features remote access, you can control your fixture from your
mobile devices.
REMOVING AND RESETTING THE DEVICE
1.
Follow the instructions for your Z-Wave certified controller to remove a
device from the Z-Wave network.
2.
Once the controller is ready to remove your device, press up and
release the toggle.
RETURNING SWITCH TO FACTORY DEFAULTS
Quickly press UP button three times, then, immediately press the DOWN
button three times.
Note: This should only be used in the event your network's primary controller
is missing or otherwise inoperable.
This device supports Association Command Class (3 Groups)
• Association Group 1 supports Lifeline, Multilevel Switch Report
• Association Group 2 supports Basic Set and is controlled
by pressing the ON or OFF button with the local load
• Association Group 3 supports Basic Set and is controlled
by double pressing the ON or OFF button
• Each Association Group supports 5 total nodes

Advertisement

loading

Summary of Contents for Honeywell ZW3004

  • Page 1 Connecting the traveler terminal of this switch to a standard, IMPORTANT! non-Honeywell switch will cause damage or result in improper function. If this The fixture controlled by the Z-Wave In-Wall Dimmer must not exceed 600W (incandescent); 150W dimmable CFL/LED. The dimmer is designed only for use with permanently switch is a part of a 3-way or 4-way multi-switch installation, do not connect installed fixtures.
  • Page 2 à trois ou quatre voies. Raccorder la borne du fil pendentif de cet Le gradateur est conçu pour être utilisé uniquement avec des appareils d’éclairage installés interrupteur à un interrupteur standard qui n'est pas de marque Honeywell entraînera de façon permanente.
  • Page 3 39357/ZW3010 Parameter and Command Class List Parameter Parameter: Length Valid value Description number OFF; OFF, O(default),1,2,3 = The device is LED is the device is LED indication LED is configuration 1 = The device is LED is the device is OFF, LED is 2 = LED always...
  • Page 4 39357/ZW3010 Parameter and Command Class List Z-Wave Plus Role Type: Always On Slave Command Class Z-Wave+ Info, Version 2 Command Class Switch Multilevel, Version 4 Command Class Association, Version 2 Command Class Association Group Info, Version 1 Command Class Manufacturer Specific, Version 2 Command Class Transport Service, Version 2 Command Class Device Reset Locally, Version 1 Command Class Power level, Version 1...

This manual is also suitable for:

39357