One channel connection

The safety device contact must be closed before the safety relay can be set in active mode.
Opening of the safety device contact inactivates the safe outputs.
One channel connection, +24 VDC static signal
One channel connection from T1
7.3

Two channels connection with equivalent contacts

Both contacts must be closed before the safety relay can be set in active mode. Opening one
or both contacts inactivate the safe outputs. Both contacts must be opened and closed before
the outputs can be activated. A short-circuit between the safety inputs is not monitored by the
safety relay if T connections are not used. In this case category 4 can only be achieved if a
safety device with short-circuit monitored outputs is connected.
Two channels connection with equivalent contacts, +24 VDC static signal