Amp Adjustment / アンプ部調整 - Yamaha HTR-5550RDS Service Manual

Av receiver/av amplifier
Hide thumbs Also See for HTR-5550RDS:
Table of Contents

Advertisement

RX-V530/RX-V530RDS/HTR-5550/HTR-5550RDS/DSP-AX530
RX-V430/RX-V430RDS/HTR-5540/HTR-5540RDS/DSP-AX430
I AMP ADJUSTMENT / アンプ部調整
Confirmation of Idling Current of Main (1) P. C. B.
• Right after power is turned on, confirm that the voltage
across the terminals of R113 (Main Lch), R133 (Main
Rch), R187 (Center), R151 (Rear Lch), R169 (Rear
Rch) are between 0.1mV and 10.0mV.
• If it exceeds 10.0mV, open (cutoff) R106 (Main Lch),
R126 (Main Rch), R183 (Center), R146 (Rear Lch),
R164 (Rear Rch) and reconfirm the voltage.
• Confirm that the voltage is 0.2mV ~ 15.0mV after 60
minutes.
42
0.1mV ~ 10.0mV
(DC)
R113 (MAIN Lch)
R133 (MAIN Rch)
R187 (CENTER)
Cut off
カット
R106 (MAIN Lch)
R126 (MAIN Rch)
R183 (CENTER)
R146 (REAR Lch)
R164 (REAR Rch)
メイン (1) 基板のアイドリング電流の確認
● 電源投入直後、R113 ( MAIN Lch) 、R133 ( MAIN Rch) 、
R187 ( CENTER) 、R151 ( REAR  Lch) 、R169 ( REAR
Rch) の端子間電圧を測定し、0.1mVから10.0mVの間で
あることを確認してください。
● 電圧が10mVを超えている場合は、R106 ( MAIN Lch) 、
R126 ( MAIN  Rch) 、R183 ( CENTER) 、R146 ( REAR
Lch) 、R164 ( REAR Rch) をカットし、電圧を再確認し
てください。
● 60分後、電圧が0.2mV〜15.0mVであることを確認して
ください。
0.1mV ~ 10.0mV
(DC)
R151 (REAR Lch)
R169 (REAR Rch)