This program has been added for testing the dryer and detecting errors.
Entering the test mode
Machine
Data Name
CARD
/COIN
Entering
the test mode
OPL
1 1
Pressing the Start button cycles to the next test function.
Number of times the Start
button is pressed
None
1 time
2 times
3 times
4 times
5 times
6 times
7 times
During check, if the door is open.
During check, if the door is closed
Note
During LqC1 test, if no buttons are pressed for 4 minutes, machine will be turned off automatically.
Do not use
.
3 4
(display)
Button
1. Entering programming mode
2. High Temp.
3. Start
1. Entering programming mode.
2. High Temp.
3. Start
Checking point
■ COIN/CARD TYPE
- ELECTRIC TYPE : US:OE
- GAS TYPE : US:Og
■ OPL TYPE
- ELECTRIC TYPE : CA:PE
- GAS TYPE : CA:Pg
PDA CHECK
Motor runs.
■ ELECTRIC TYPE: Heater runs.
Motor + Heater 1 (2700W)
■ GAS TYPE: GAS valve runs.
Motor + Valve
■ ELECTRIC TYPE: Heater runs.
Motor + Heater 1 +Heater 2 (5400W)
■ GAS TYPE: GAS valve runs.
Motor+Valve
LED & KEY CHECK
Press High Temp. button.
Press Med Temp. button.
Press Low Temp. button.
Press No Heat button.
Test ends.
Door switch
(Motor & Heater Off, Buzzer beeps seven
times)
Test goes back at step 2.
(Motor on & Heater Off)
Test Mode
Display
Insert service card (card type), Turn on/off toggle switch (Coin type).
Press the High Temp. button.
Then
appears in the display.
Enter the diagnostic test mode.
Push and hold the High Temp. and Low Temp. at the same time.
After that push Med Temp. button for 3 times. Push Start button.
Press the High Temp. button.
Then
appears in the display.
Enter the diagnostic test mode.
LqC 1
Version and code of machine (All LED on)
CARD/COIN machine - Display US:OE or
US:Og and gU:XX
alternately. OPL machine – Display CA:PE or
CA:Pg and gU:XX
alternately. XX is the version number
Ir--
Measured moisture value (70~239)
Current temperature (5~70)
(Displays the temperature inside the drum in
° Celsius.)
Current temperature (5~70)
(Displays the temperature inside the drum in
° Celsius.)
Version and code of machine
LqC1
dE
(The door is open. Please close the door
completely)
Measured moisture value (70~239)
Description