Note
When setting the linear scan area, make sure the target area is both included in the optical
channel and the thermal channel.

8.6 Set Limit

The device can only move within the limited range.
Steps
1. Go to Configuration → PTZ → Limit .
2. Select Limit Type.
Manual Stops
It refers to the movement range limit when you control the device manually.
Scan Stops
It refers to the movement range limit when the device scans automatically.
Note
Scan limit is only supported by the device that has scan function.
3. Click Set and set limits according to the prompt on the live image.
4. Optional: Click Clear to clear the limit settings of the selected mode.
5. Click Save.
6. Check Enable Limit.
Note
If you need to cancel all the set patrol paths, go to Configuration → PTZ → Clear Config , select
Clear All PTZ Limited, and click Save.
Result
The device can only move within the set region after saving the settings.

8.7 Set Initial Position

Initial position refers to the relative initial position of the device azimuth. You can set the initial
position if you need to select one point in the scene as the base point.
Steps
1. Go to Configuration → PTZ → Initial Position .
2. Move the device to the needed position by manually controlling the PTZ control buttons.
3. Click Set to save the information of initial position.
Call
The device moves to the set initial position.
46