Unpacking The Heater - Bosch C 950 Installation And Operation Instruction Manual

Indoor model
Table of Contents

Advertisement

Technical characteristics
Frequency
Amperage
Idle
Operation
Noise
3)
Water protection
1) To measure Gas Pressure, see Measuring Gas Pressure, chapter 4.14, page 49.
2) Activation varies with inlet water temperatures from 0.5 - 1.6 gallon/minute (1.9 - 6.1 l/m).
3) Protection against water drops.
Table 3
If appliance is installed at elevations above 2000ft, refer to
chapter 4.3.8 Fan speed adjustment.
Safety devices
Flame failure device (ionization flame rod sensor)
Overheat prevention (temperature limiter)
Inlet temperature sensor
Outlet temperature sensor
Back flow temperature sensor
Exhaust gas temperature sensor
3.3

Unpacking the heater

Before installing the unit, be certain you have the correct
heater for your type of Gas - Propane or Natural Gas.
Identification labels are found on the shipping box, and on the
rating plate which is located on the right side panel of the cover.
Fig. 2
Rating plate
[1] Serial number
[2] Type of gas
C 950/C 1050 (Pro TL 175 C/199 C) – 6 720 805 440 (2019/10)
Units
C 950 ES (Pro TL 175C) C 1050 ES (Pro TL 199C)
Hz
mA
A
db (A)
IP
3.3.1 The box includes
Greentherm water heater
Bracket for wall hanging the heater
Exhaust vent adaptor (with 4 screws and gasket provided)
Combustion air inlet adaptor (with 3 screws and gasket
provided)
Installation manual (manual can be downloaded at
www.boschheatingandcooling.com.)
Product registration card
Energy Guide label
Please complete and return the enclosed product registration
card.
The Greentherm is not approved or designed for:
Manufactured (mobile) homes, boats or any mobile
installation. (Modular homes are acceptable for
installation).
Use above 8000 ft A.S.L. altitude (see page 33).
Outdoor installation without installation of Outdoor kit
(BTOK): Outdoor installations in areas where annual
minimum temperatures are below 15 °F.
Applications where inlet water temperature is higher
than 140 °F (60 °C). In these applications a 3 way valve
or thermostatic mixing valve must be installed to
prevent inlet water temperatures > than 140 °F (60 °C).
Appliance details
60
40
≤ 2.5
45 - 65
X4D
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

C 1050 esPro tl 175cPro tl 199c

Table of Contents