PRECAUTIONS TO BE OBSERVED
BEFORE AND DURING SERVICING
TO AVOID POSSIBLE EXPOSURE TO
EXCESSIVE MICROWAVE
4
PRECAUTIONS TO BE OBSERVED BEFORE
AND DURING SERVICING TO AVOID POSSIBLE
EXPOSURE
ENERGY
a) Do not operate or allow the oven to be operated with
the door open.
b) Make the following safety checks on all ovens to be
serviced before activating the magnetron or other
microwave source, and make repairs as necessary:
interlock operation, proper door closing, seal and
sealing surfaces (arcing, wear, and other damage),
damage to or loosening of hinges and latches,
evidence of dropping or abuse).
c) Before turning on microwave power for any service
test or inspection within the microwave generating
compartment, check the magnetron, wave guide or
transmission line, and cavity for proper alignment,
integrity and connection.
d) Any defective or misadjusted components in the
interlock,
generation and transmission systems, shall be
repaired, replaced, or adjusted by procedures
described in this manual before the oven is released
to the owner.
e) A microwave leakage check, to verify compliance
with the Federal Performance Standard, should be
performed on each oven prior to release to the
owner.
TO
EXCESSIVE
monitor,
door
ENERGY
MICROWAVE
seal,
and
microwave
7