Wiring
About your new thermostat
Wiring TrueIAQ
with a
®
humidifier and HRV/ERV
ventilator.
1
TrueIAQ
R
C
68
40
In
%
SENSOR
76
55
Out
%
:
SENSOR
12 15
PM
SWITCH
W
G
VENT
VENT
DEHUM
DEHUM
HUM
HUM
IF A THERMOSTAT OTHER THAN A TH5110, TH5220, TH5320, TH6110, TH6220,
1
TH6320, TH8110, TH8320 OR TH8321 IS USED, A RELAY MAY BE REQUIRED TO
ISOLATE THE G WIRE.
FOR WIRING OF HUMIDIFIER OTHER THAN THE HE100 OR HE200 READ THE
2
INSTALLATION INSTRUCTIONS.
15
TH8110U
R Rc
C
W
Y
G
OUTDOOR
SENSOR
(PROVIDED)
HE100
HE200
R
C
24 VOLT/40VA
TRANSFORMER
L2
L1
R
C
W
HVAC
Y
G
ERV/HRV
RED
BLACK
GREEN
2
M32536